Sample Record
Owner Lab
- CT HQ - Sacramento Hot Mix Asphalt Laboratory
DIME Sample ID 2019-08-07-30
Project Information
| Project Identifiers | Project ID: 213283 DEA: 060U09U4 EFIS: 0616000243 |
|---|---|
| DIST-CO-RTE-PM | 06-FRE-168-R36.0/65.9 |
| Award Date | 08/24/2018 |
| Closeout Date | 01/31/2020 |
| Work Description | HMA RESURFACING AND REHAB CULVERTS |
| Location Description | FRESNO COUNTY IN AND NEAR SHAVER LAKE FROM 0.2 MILE WEST OF AUBERRY ROAD TO KAISER PASS ROAD |
| QA Service Level | 1 (Verified on 09/25/2018) |
Sample Information
| Sample Taken Date | 08/07/2019 | Sample Unique Key | 30 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/18/2019 |
| Sample type | Dispute Resolution | A brief description of the sample | 3/4" HMA SP R13 - PG 64-28 |
| The quantity of what the sample constitutes | 2 | From where was the sample collected | Source |
| First name of sampler or witnessed by | MH | Last name of sampler or witnessed by | S |
| Title of sampler | TE | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Vulcan Ashlan | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 2 |
| Sublot number | 8 | HMA Mix Number | Not set |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| 2019-08-07-30-1 | AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content) | Frank Chavez, CT HQ - Sacramento Hot Mix Asphalt Laboratory | 09/23/2019 | No | T-308 (Mass of Aggregate prior to ignition and mass of aggregate remaining after ignition is an average of two samples |
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2019-08-07-30-1 AASHTO T308-10