Sample Record
Owner Lab
- CT HQ - QASI Los Angeles Field Office
DIME Sample ID 2019-12-17-2
Project Information
| Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 12/17/2019 | Sample Unique Key | 2 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | Not set |
| Sample type | Authorization | A brief description of the sample | #6 2' Diameter Hoops |
| The quantity of what the sample constitutes | 10 of 15 samples from welder N101 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Weeks |
| Title of sampler | ASI | Telephone number of sampler | 310-883-8369 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | CMC Etiwanda | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L79-197-19 | Structure unique identifier | |
| Structure name | NA | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 4092425 |
| Hoop Manufacturer Lot Number(s) | Lot 1 Welding Machine N101 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | 6 |
| Diameter of Hoop | 2'-0" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | CMC |
| Welding Company | CMC Etiwanda | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| 2019-12-17-2-1 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical) | fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory | 01/06/2020 | 01/06/2020 | No | Cycle-1 Ok Necking | |||
| 2019-12-17-2-2 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical) | fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory | 01/06/2020 | 01/06/2020 | No | Cycle-2 Ok Necking | |||
| 2019-12-17-2-3 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical) | fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory | 01/06/2020 | 01/06/2020 | No | Cycle-3 Ok Necking | |||
| 2019-12-17-2-4 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical) | fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory | 01/06/2020 | 01/06/2020 | No | Cycle-4 Ok Necking | |||
| 2019-12-17-2-5 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical) | fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory | 01/06/2020 | 01/06/2020 | No | Break-5 Ok Necking | |||
| 2019-12-17-2-6 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical) | fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory | 01/06/2020 | 01/06/2020 | No | Break-6 Ok Necking | |||
| 2019-12-17-2-7 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical) | fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory | 01/06/2020 | 01/06/2020 | No | Break-7 Ok Necking | |||
| 2019-12-17-2-8 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical) | fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory | 01/06/2020 | 01/06/2020 | No | Break-8 Ok Necking |
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2019-12-17-2-1 CTM 670-December 2013
DIME Test ID: 2019-12-17-2-2 CTM 670-December 2013
DIME Test ID: 2019-12-17-2-3 CTM 670-December 2013
DIME Test ID: 2019-12-17-2-4 CTM 670-December 2013
DIME Test ID: 2019-12-17-2-5 CTM 670-December 2013
DIME Test ID: 2019-12-17-2-6 CTM 670-December 2013
DIME Test ID: 2019-12-17-2-7 CTM 670-December 2013