Sample Record
Owner Lab
- CT HQ - QASI Sacramento Field Office
DIME Sample ID 2019-12-11-11
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 212794 DEA: 024F7804 EFIS: 0213000032 |
|---|---|
| DIST-CO-RTE-PM | 02-SHA,LAS,PLU,SHA,SIS,TRI-5-22087-25.7 |
| Award Date | 12/20/2018 |
| Closeout Date | 10/20/2021 |
| Work Description | CMS SIGNS IN SHASTA COUNTY |
| Location Description | IN BUTTE, LASSEN, PLUMAS, SHASTA, SISKIYOU AND TRINITY COUNTIES IN VARIOUS LOCATIONS. |
| QA Service Level | 1 (Verified on 01/08/2019) |
Sample Information
| Sample Taken Date | 12/11/2019 | Sample Unique Key | 11 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/18/2019 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4-10 x 2 1/4" A325 HVY HX MG NUT |
| The quantity of what the sample constitutes | 45 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Jane | Last name of sampler or witnessed by | Lillard |
| Title of sampler | CALTRANS METS QA INSPECTOR | Telephone number of sampler | 916-308-9430 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Structural and Steel Products | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | S52-031-19 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 100897462 | Nut Mfg. Lot Number(s) | |
| Washer Mfg. Lot Number(s) | Bolt Specification | A325 | |
| Bolt Length(s) | 2 1/4" | Nut Specification | n/a |
| Washer Specification | n/a | Finish | Mechanically Galvanized to ASTM B695 |
| Diameter/Size | 3/4" | Bolt Mfg. Lot Number | 424371B |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | not required | |
| Washer Inner Diameter(s) |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2019-12-11-11-1 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-12-11-11-2 ASTM B499-14 (Verified)
DIME Test ID: 2019-12-11-11-3 ASTM E18-15 (Verified)