Sample Record
Owner Lab
- CT D08 - Fontana Southern Regional Laboratory
DIME Sample ID 2019-11-01-14
Project Information
| Project Identifiers | Project ID: 210569 DEA: 083555V4 EFIS: 0814000086 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-15-42.5/46.0 |
| Award Date | 11/05/2015 |
| Closeout Date | 01/18/2022 |
| Work Description | WIDEN I-15, RECONSTRUCT 3 IC'S, CONSTRUCT 2 NEW BR AND WIDEN 3 BR. |
| Location Description | SAN BERNARDINO COUNTY IN VICTORVILLE FROM 0.5 MILE NORTH OF MOJAVE DRIVE TO 1.5 MILE NORTH OF STODDARD WELLS ROAD OVERCROSSING |
| QA Service Level | 1 (Verified on 10/15/2015) |
Sample Information
| Sample Taken Date | 11/01/2019 | Sample Unique Key | 14 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/05/2019 |
| Sample type | Department Acceptance | A brief description of the sample | 1" HMA-A R15 PG 64-28M (1.0% Lime Slurry) |
| The quantity of what the sample constitutes | 2 boxes | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | QC | Last name of sampler or witnessed by | QC |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 0678A-19 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Blue Diamond-Victorville | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 1 inch | Lot number | Unknown |
| Sublot number | Unknown | HMA Mix Number | Not set |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| 2019-11-01-14-1 | AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content) | Angelito Villegas, CT D08 - Fontana Southern Regional Laboratory | 11/01/2019 | No |
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2019-11-01-14-1 AASHTO T308-10