Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2019-10-08-3

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 213411
DEA: 030H10U4
EFIS: 0317000246
DIST-CO-RTE-PM03-SAC-5-9.7/24.9
Award Date05/01/2019
Closeout Date02/22/2024
Work DescriptionNot set
Location DescriptionConstruction on state highway in Sacramento County in and near Sacramento from 1.1 miles south of Elk Grove Boulevard to American River Viaduct
QA Service Level1 (Verified on 07/19/2019)

Sample Information

Sample Taken Date10/08/2019 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing10/11/2019 Sample typeQuality Assurance
A brief description of the sample#6 Hoops The quantity of what the sample constitutes8
From where was the sample collectedFabricator First name of sampler or witnessed byRigoberto
Last name of sampler or witnessed byMarin Title of samplerCT METS QA INSPECTOR
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameRKR Steel Welding
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL133-010-19
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)1922100
Hoop Manufacturer Lot Number(s)1, 5 Material Standard CodeASTM A615
Material Grade60 Rebar Size6
Diameter of Hoop3'-8" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerVinton Steel
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2019-10-08-3-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory10/16/201910/16/2019
Yes
10/16/2019Bar Broke, Ok NeckingPublic - Test Data Visible
2019-10-08-3-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory10/16/201910/16/2019
Yes
10/16/2019Bar Broke, Ok NeckingPublic - Test Data Visible
2019-10-08-3-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory10/16/201910/16/2019
Yes
10/16/2019Bar Broke, Ok NeckingPublic - Test Data Visible
2019-10-08-3-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory10/16/201910/16/2019
Yes
10/16/2019Bar Broke, Ok NeckingPublic - Test Data Visible
2019-10-08-3-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory10/16/201910/16/2019
Yes
10/16/2019Bar Broke, Ok NeckingPublic - Test Data Visible
2019-10-08-3-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory10/16/201910/16/2019
Yes
10/16/2019Bar Broke, Ok NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-10-08-3-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-10-08-3-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-10-08-3-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-10-08-3-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-10-08-3-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-10-08-3-6 CTM 670-December 2013 (Verified)