Sample Record
DIME Sample ID 2019-09-21-2
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 214272 DEA: 101L1504 EFIS: 1019000196 |
|---|---|
| DIST-CO-RTE-PM | 10-ALP-89-21.47, 21.46 |
| Award Date | 07/14/2019 |
| Closeout Date | 01/05/2023 |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 08/02/2019) |
Owner Lab
- CT HQ - Sacramento Concrete Testing Laboratory
Sample Information
| Sample Taken Date | 09/21/2019 | Sample Unique Key | 2 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/25/2019 | Sample type | Quality Assurance |
| A brief description of the sample | 6x12 concrete cylinders | The quantity of what the sample constitutes | two |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Phoebe |
| Last name of sampler or witnessed by | Tran | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Jobsite | |
| Transportation Laboratory (TL) Number | 001 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 0000 |
|---|---|---|---|
| The truck number from where the sample was collected | Unknown | The batch plant ticket number from where the sample was collected | 0000000000 |
| Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
| A detailed description of where the material sample was collected | Jobsite | Where the material sample would have been placed if not sampled | Unknown |
| From Lot No. | Unknown | Bag Lot No. | Unknown |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2019-09-21-2-1 ASTM C39-17a (Verified)