Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2019-08-30-5
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 213357 DEA: 024F2004 EFIS: 0212000071 |
---|---|
DIST-CO-RTE-PM | 02-SHA-44-59.4/59.8 |
Award Date | 11/02/2018 |
Closeout Date | 01/04/2021 |
Work Description | BRIDGE REPLACEMENT |
Location Description | SHASTA COUNTY NEAR OLD STATION FROM 0.3 MILE WEST TO 0.2 MILE EAST OF HAT CREEK BRIDGE |
QA Service Level | 1 (Verified on 06/21/2018) |
Sample Information
Sample Taken Date | 08/30/2019 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/04/2019 |
Sample type | Quality Assurance | A brief description of the sample | Epoxy Coated Rebar |
The quantity of what the sample constitutes | 10 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Ryan | Last name of sampler or witnessed by | Cummings |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Farwest | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S29-150-19 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM7 - Epoxy Coated Rebar | Rebar Heat Number(s) | 228319 122719 308519 228219 079319 |
---|---|---|---|
Rebar Epoxy Batch Number(s) | 9396029471 9196029155 9396029515 9196029155 | Rebar Coating Specification | ASTM A775 |
Rebar Size (#) | 4 #5 #9 | Rebar Coating Color | Green |
Rebar Manufacturer | Farwest | Rebar Coater | valspar |
Rebar Powder Manufacturer | Unknown | Release Number | Unknown |
Quality Assurance Code | Unknown |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2019-08-30-5-1 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-08-30-5-2 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-08-30-5-3 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-08-30-5-4 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-08-30-5-5 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-08-30-5-6 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-08-30-5-7 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-08-30-5-8 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-08-30-5-9 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-08-30-5-10 ASTM A775-07b-re14 (Verified)