Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2019-08-30-5

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 213357
DEA: 024F2004
EFIS: 0212000071
DIST-CO-RTE-PM02-SHA-44-59.4/59.8
Award Date11/02/2018
Closeout Date01/04/2021
Work DescriptionBRIDGE REPLACEMENT
Location DescriptionSHASTA COUNTY NEAR OLD STATION FROM 0.3 MILE WEST TO 0.2 MILE EAST OF HAT CREEK BRIDGE
QA Service Level1 (Verified on 06/21/2018)

Sample Information

Sample Taken Date08/30/2019 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/04/2019
Sample typeQuality Assurance A brief description of the sampleEpoxy Coated Rebar
The quantity of what the sample constitutes10 From where was the sample collectedManufacturer
First name of sampler or witnessed byRyan Last name of sampler or witnessed byCummings
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameFarwest Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormS29-150-19 Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM7 - Epoxy Coated Rebar Rebar Heat Number(s)228319 122719 308519 228219 079319
Rebar Epoxy Batch Number(s)9396029471 9196029155 9396029515 9196029155 Rebar Coating SpecificationASTM A775
Rebar Size (#)4 #5 #9 Rebar Coating ColorGreen
Rebar ManufacturerFarwest Rebar Coatervalspar
Rebar Powder ManufacturerUnknown Release NumberUnknown
Quality Assurance CodeUnknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2019-08-30-5-1ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory09/05/2019
Yes
09/05/2019Heat # 228319 Bar 1&2 Public - Test Data Visible
2019-08-30-5-2ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory09/05/2019
Yes
09/05/2019Heat # 228319 Bar 1&2Public - Test Data Visible
2019-08-30-5-3ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory09/05/2019
Yes
09/05/2019Heat # 122719 Bar 3&4Public - Test Data Visible
2019-08-30-5-4ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory09/05/2019
Yes
09/05/2019Heat # 122719 Bar 3&4Public - Test Data Visible
2019-08-30-5-5ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory09/05/2019
Yes
09/05/2019Heat # 308519 Bar 5&6Public - Test Data Visible
2019-08-30-5-6ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory09/05/2019
Yes
09/05/2019Heat # 308519 Bar 5&6Public - Test Data Visible
2019-08-30-5-7ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory09/05/2019
Yes
09/05/2019Heat # 228219 Bar 7&8Public - Test Data Visible
2019-08-30-5-8ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory09/05/2019
Yes
09/05/2019Heat # 228219 Bar 7&8Public - Test Data Visible
2019-08-30-5-9ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory09/05/2019
Yes
09/05/2019Heat # 079319 Bar 9&10Public - Test Data Visible
2019-08-30-5-10ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory09/05/2019
Yes
09/05/2019Heat # 079319 Bar 9&10Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-08-30-5-1 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-08-30-5-2 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-08-30-5-3 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-08-30-5-4 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-08-30-5-5 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-08-30-5-6 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-08-30-5-7 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-08-30-5-8 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-08-30-5-9 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-08-30-5-10 ASTM A775-07b-re14 (Verified)