Sample Record

DIME Sample ID 2019-08-23-6

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211775
DEA: 024E6504
EFIS: 0212000012
DIST-CO-RTE-PM02-SIS-96-R52.5/88.4
Award Date07/10/2017
Closeout Date01/05/2021
Work DescriptionWIDEN BRIDGES,POLYESTER CONC OVERLAY,COLD PLANE AC PVMT,HMA,GUARDRAIL
Location DescriptionSISKIYOU COUNTY NEAR SEIAD VALLEY AT VARIOUS LOCATIONS FROM 0.1 MILE WEST OF THOMPSON CREEK BRIDGE TO 0.2 MILE EAST OF BEAVER CREEK BRIDGE
QA Service Level1 (Verified on 08/23/2017)

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

Sample Information

Sample Taken Date08/23/2019 Sample Unique Key6
Date that the sample was received by the laboratory/organization performing the testing08/27/2019 Sample typeQuality Assurance
A brief description of the sample#6 welded hoops 1'-8" diameter The quantity of what the sample constitutes132
From where was the sample collectedFabricator First name of sampler or witnessed bySteve
Last name of sampler or witnessed byHall Title of samplerCALTRANS METS QA INSPECTOR
Telephone number of sampler6466327821 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameRKR Steel Welding
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)9001269
Hoop Manufacturer Lot Number(s)2 Material Standard CodeASTM A706
Material Grade60 Rebar Size6
Diameter of Hoop1'-8" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Steel CA
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2019-08-23-6-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory08/30/201908/30/2019
Yes
09/03/2019Bar Broke, Ok NeckingPublic - Test Data Visible
2019-08-23-6-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory08/30/201908/30/2019
Yes
09/03/2019Bar Broke, Ok NeckingPublic - Test Data Visible
2019-08-23-6-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory08/30/201908/30/2019
Yes
09/03/2019Bar Broke, Ok NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-08-23-6-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-08-23-6-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-08-23-6-3 CTM 670-December 2013 (Verified)