| Project Identifiers | Project ID: 212244 DEA: 044G8404 EFIS: 0413000051 |
|---|---|
| DIST-CO-RTE-PM | 04-NAP-128-20.1/20.4 |
| Award Date | 02/19/2019 |
| Closeout Date | 06/27/2023 |
| Work Description | REPLACE CAPELL CREEK BRIDGE |
| Location Description | NAPA COUNTY ABOUT 15 MILES EAST OF RUTHERFORD FROM 1.1 MILES EAST OF KNOXVILLE ROAD TO 0.3 MILE WEST OF CAPELL VALLEY CREST |
| QA Service Level | 1 (Verified on 05/20/2017) |
Owner Lab
- CT HQ - QASI Los Angeles Field Office
Sample Information
| Sample Taken Date | 07/02/2019 | Sample Unique Key | 5 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/02/2019 | Sample type | Quality Assurance |
| A brief description of the sample | Flash Welded Hoops | The quantity of what the sample constitutes | 4 ea from lots 1 and 2 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Subramony |
| Last name of sampler or witnessed by | Krishnamoorthy | Title of sampler | QAI |
| Telephone number of sampler | 9514366777 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | RKR Steel Welding | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L88-003-2019 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 4086359 |
| Hoop Manufacturer Lot Number(s) | Lots 1 and 2 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | 8 |
| Diameter of Hoop | 10'-0" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | CMC Rebar |
| Welding Company | RKR Steel Welding | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2019-07-02-5-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-07-02-5-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-07-02-5-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-07-02-5-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-07-02-5-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-07-02-5-6 CTM 670-December 2013 (Verified)