Sample Record

DIME Sample ID 2019-06-05-4

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 213469
DEA: 024C40V4
EFIS: 0218000125
DIST-CO-RTE-PM02-SHA-5-R3.8/R11.7
Award Date11/06/2018
Closeout Date08/16/2023
Work DescriptionWIDEN TO 6 LANES, BRIDGE REPLACEMENT AND WIDENING AND ROADWAY REHAB
Location DescriptionSHASTA COUNTY IN AND NEAR ANDERSON FROM ROUTE 5/273 SEPARATION TO 0.4 MILE SOUTH OF CHURN CREEK ROAD OVERCROSSING
QA Service Level1 (Verified on 12/31/2018)

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

Sample Information

Sample Taken Date06/05/2019 Sample Unique Key4
Date that the sample was received by the laboratory/organization performing the testing06/06/2019 Sample typeQuality Assurance
A brief description of the sample#6 ASTM A706 Grade 60 Hoops The quantity of what the sample constitutes2 lots (300)
From where was the sample collectedFabricator First name of sampler or witnessed byOsiel
Last name of sampler or witnessed byRamirez Title of samplerCT METS QA INSPECTOR
Telephone number of sampler5599740870 Laboratory sample identification0
Linked DIME Sample ID2019-05-07-3 The fabricator/manufacturer/facility nameCMC Rebar
Transportation Laboratory (TL) Number0 Inspector Lot Number from the Transportation Laboratory (TL) FormL123-038-19
Structure unique identifier42-5843 Structure nameUnknown
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4086165
Hoop Manufacturer Lot Number(s)8A, 11A Material Standard CodeASTM A706
Material Grade60 Rebar Size6
Diameter of Hoop1'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Arizona
Welding CompanyCMC Rebar (Etiwanda) Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2019-06-05-4-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/07/201906/07/2019
Yes
06/14/2019Bar Broke; OK NeckingPublic - Test Data Visible
2019-06-05-4-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/07/201906/07/2019
Yes
06/14/2019Bar Broke; OK NeckingPublic - Test Data Visible
2019-06-05-4-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/07/201906/07/2019
Yes
06/14/2019Bar Broke; OK NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-06-05-4-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-06-05-4-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-06-05-4-3 CTM 670-December 2013 (Verified)