Sample Record

DIME Sample ID 2019-05-02-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 212993
DEA: 033F5304
EFIS: 0313000135
DIST-CO-RTE-PM03-ED-50-67.3
Award Date11/09/2018
Closeout Date09/20/2022
Work DescriptionECHO SUMMIT BRIDGE IS A 24-FT WIDE, THREE-SPAN, REINFORCED CONCRETE GIRDER BRIDGE
Location DescriptionEL DORADO COUNTY NEAR MEYERS AT ECHO SUMMIT SIDEHILL VIADUCT
QA Service Level1 (Verified on 01/08/2019)

Owner Lab

  • CT HQ - QASI Bay Area Field Office

Sample Information

Sample Taken Date05/02/2019 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing05/02/2019 Sample typeQuality Assurance
A brief description of the sampleA706 T-headed rebar The quantity of what the sample constitutes150
From where was the sample collectedFabricator First name of sampler or witnessed byEd
Last name of sampler or witnessed byFleming Title of samplerTET
Telephone number of sampler707-310-2029 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameHarris Rebar
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormB10-136-19
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingAuthorization Testing
Rebar Heat Number(s)3500005660 Head Manufacturer Lot Number(s)9BNX-6R1
Rebar Size9 Headed Bar Model NameBarsplice Buttonhead
Size of HeadFull Size - 9x Head Connection TypeCrimped Head
Head ShapeCircular Rebar ManufacturerNucor
Head ManufacturerBarsplice Head FabricatorBarsplice
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2019-05-02-1-1ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory05/03/201905/03/2019
Yes
05/10/2019Bar Broke; OK NeckingPublic - Test Data Visible
2019-05-02-1-2ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory05/03/201905/03/2019
Yes
05/10/2019Bar Broke; OK NeckingPublic - Test Data Visible
2019-05-02-1-3ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory05/03/201905/03/2019
Yes
05/10/2019Bar Broke; OK NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-05-02-1-1 ASTM A970-15e1 (Verified)
DIME Test ID: 2019-05-02-1-2 ASTM A970-15e1 (Verified)
DIME Test ID: 2019-05-02-1-3 ASTM A970-15e1 (Verified)