Sample Record

Owner Lab

  • CT HQ - QASI Bay Area Field Office

DIME Sample ID 2019-04-24-5

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 212993
DEA: 033F5304
EFIS: 0313000135
DIST-CO-RTE-PM03-ED-50-67.3
Award Date11/09/2018
Closeout Date09/20/2022
Work DescriptionECHO SUMMIT BRIDGE IS A 24-FT WIDE, THREE-SPAN, REINFORCED CONCRETE GIRDER BRIDGE
Location DescriptionEL DORADO COUNTY NEAR MEYERS AT ECHO SUMMIT SIDEHILL VIADUCT
QA Service Level1 (Verified on 01/08/2019)

Sample Information

Sample Taken Date04/24/2019 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/25/2019
Sample typeQuality Assurance A brief description of the sampleHeaded Rebar
The quantity of what the sample constitutes150 From where was the sample collectedFabricator
First name of sampler or witnessed byEd Last name of sampler or witnessed byFleming
Title of samplerTET Telephone number of sampler707-310-2029
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHarris Rebar Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB10-131-19 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingAuthorization Testing
Rebar Heat Number(s)3500001677 Head Manufacturer Lot Number(s)6R1
Rebar Size9 Headed Bar Model Name9 BNX6R1
Size of HeadFull Size - 9x Head Connection TypeCrimped Head
Head ShapeCircular Rebar ManufacturerNucor
Head ManufacturerBarsplice Head FabricatorBarsplice
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2019-04-24-5-1ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory04/26/2019Brian
Yes
05/07/2019Bar Broke; OK Necking
2019-04-24-5-2ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory04/26/2019Brian
Yes
05/07/2019Head Slipped
2019-04-24-5-3ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory04/26/2019Brian
Yes
05/07/2019Head Slipped
2019-04-24-5-4ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory04/26/2019Brian
Yes
05/07/2019Bar Broke; OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-04-24-5-1 ASTM A970-15e1 (Verified)
DIME Test ID: 2019-04-24-5-2 ASTM A970-15e1 (Verified)
DIME Test ID: 2019-04-24-5-3 ASTM A970-15e1 (Verified)
DIME Test ID: 2019-04-24-5-4 ASTM A970-15e1 (Verified)