Sample Record

DIME Sample ID 2019-03-11-14

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 3807
DEA: 07121844
EFIS: 0700000117
DIST-CO-RTE-PM07-LA-5-42.8/47.3
Award Date12/06/2010
Closeout Date06/30/2021
Work DescriptionCONSTRUCT HOV LANES, RETAINING WALLS AND SOUND WALLS.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES, GLENDALE, AND BURBANK FROM ROUTE 5/134 SEPARATION TO MAGNOLIA BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 02/23/2012)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date03/11/2019 Sample Unique Key14
Date that the sample was received by the laboratory/organization performing the testing04/15/2019 Sample typeQuality Assurance
A brief description of the sampleLap Splice The quantity of what the sample constitutes4
From where was the sample collectedManufacturer First name of sampler or witnessed byBryan
Last name of sampler or witnessed byNagid Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameBarSplice
Transportation Laboratory (TL) NumberC686597 Inspector Lot Number from the Transportation Laboratory (TL) FormNA
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerGerdau
Coupler ManufacturerBarSplice Intermediate Assembler or FabricatorUnknown
Rebar Size6 Coupler ModelDBL BRL Zap Screwlok
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)8249 Rebar Heat Number(s) 65033074
Rebar Size 2 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2019-03-11-14-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory04/17/201904/17/2019
Yes
04/25/2019Bar Broke; OK NeckingPublic - Test Data Visible
2019-03-11-14-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory04/17/201904/17/2019
Yes
04/25/2019Bar Broke; OK NeckingPublic - Test Data Visible
2019-03-11-14-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory04/17/201904/17/2019
Yes
04/25/2019Bar Broke; OK NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-03-11-14-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-03-11-14-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-03-11-14-3 CTM 670-December 2013 (Verified)