Sample Record

DIME Sample ID 2019-04-09-2

Project Information

Project IdentifiersProject ID: 99999
DEA: 0322222
DIST-CO-RTE-PM03-SAC,OMG-888,99,80-0.6-0.6
Award DateNot set
Closeout DateNot set
Work DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
QA Service Level (Verified on 04/05/2013)

Owner Lab

  • CT HQ - Sacramento Materials Management Branch Field Office

Sample Information

Sample Taken Date04/09/2019 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing04/03/2019 Sample typeQuality Assurance
A brief description of the sampleCoupler The quantity of what the sample constitutes4
From where was the sample collectedJob Site First name of sampler or witnessed byS
Last name of sampler or witnessed byFIERRO Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameDayton Superior CMC Rebar
Transportation Laboratory (TL) NumberC527107 Inspector Lot Number from the Transportation Laboratory (TL) FormNA
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A615
Material Grade40 Rebar ManufacturerTNT
Coupler ManufacturerUnknown Intermediate Assembler or FabricatorUnknown
Rebar Size5 Coupler Model232323
Coating StandardsASTM A934 epoxy Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)123 Rebar Heat Number(s)44444
Rebar Size 2 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2019-04-09-2-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory04/09/201904/09/2019
No
OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-04-09-2-1 CTM 670-December 2013