Sample Record
Owner Lab
- CT HQ - Sacramento Cement Testing Laboratory
DIME Sample ID 2019-03-01-5
Project Information
| Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 03/01/2019 | Sample Unique Key | 5 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 03/01/2019 | Sample type | Preliminary |
| A brief description of the sample | Class N Pozzolan | The quantity of what the sample constitutes | 1 Bucket |
| From where was the sample collected | Source | First name of sampler or witnessed by | Unknown |
| Last name of sampler or witnessed by | Unknown | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | CM192903 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Geofortis | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | Cementitious | Brand | Geofortis |
|---|---|---|---|
| Mill | 45 45 10 Blend | Type of Cementitious Material | Class F or N Flyash |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| 2019-03-01-5-4 | ASTM C430-8: Standard Test Method for Fineness of Hydraulic Cement by the 45-μm (No. 325) Sieve | Stephen Donnelly, CT HQ - Sacramento Cement Testing Laboratory | 04/30/2019 | No | |||||
| 2019-03-01-5-6 | ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens) | Spencer Adams, CT HQ - Sacramento Cement Testing Laboratory | 05/23/2019 | No | |||||
| 2019-03-01-5-7 | ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens) | Spencer Adams, CT HQ - Sacramento Cement Testing Laboratory | 06/13/2019 | No |
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2019-03-01-5-4 ASTM C430-8
DIME Test ID: 2019-03-01-5-6 ASTM C109-16a
DIME Test ID: 2019-03-01-5-7 ASTM C109-16a