Sample Record

Owner Lab

  • CT HQ - Sacramento Cement Testing Laboratory

DIME Sample ID 2019-02-27-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date02/27/2019 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/14/2019
Sample typeDepartment Acceptance A brief description of the sampleRapid Setting Cement
The quantity of what the sample constitutes1 Bucket From where was the sample collectedJob Site
First name of sampler or witnessed byUnknown Last name of sampler or witnessed byUnknown
Title of sampler Telephone number of sampler
Laboratory sample identificationCM194901 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCTS Rapid Set Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeCementitious BrandCTS
MillUnknown Type of Cementitious MaterialRapid Set Cement

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2019-02-27-1-1ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)Ben Lenz, CT HQ - Sacramento Cement Testing Laboratory03/15/2019Spencer Adams
Yes
05/11/2022
2019-02-27-1-2CTM 553-1: Method for Testing Thermal Stability of Mortar Made with Hydraulic CementBenjamin Lenz, CT HQ - Sacramento Cement Testing Laboratory03/15/2019Benjamin Lenz
Yes
05/11/2022
2019-02-27-1-3CTM 527-February 2014: Method of Test for Expansion in Water and Contraction in Air of Portland Cement MortarBenjamin Lenz, CT HQ - Sacramento Cement Testing Laboratory03/25/2019Benjamin Lenz
Yes
05/11/2022
2019-02-27-1-4ASTM C1038-14b: Standard Test Method for Expansion of Hydraulic Cement Mortar Bars Stored in Water (Cement Mortar Bars)Benjamin Lenz, CT HQ - Sacramento Cement Testing Laboratory03/26/2019Benjamin Lenz
Yes
05/11/2022An unrecoverable error was made taking measurements for Specimen C. To keep the final result correct, 0 is entered as the initial value and the final value is the average of the other three values.

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-02-27-1-1 ASTM C109-16a (Verified)
DIME Test ID: 2019-02-27-1-2 CTM 553-1 (Verified)
DIME Test ID: 2019-02-27-1-3 CTM 527-February 2014 (Verified)
DIME Test ID: 2019-02-27-1-4 ASTM C1038-14b (Verified)