Sample Record

DIME Sample ID 2018-10-04-2

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 212687
DEA: 06442544
EFIS: 0612000175
DIST-CO-RTE-PM06-KER-46,5-31.5-33.2
Award Date01/11/2018
Closeout Date11/19/2021
Work DescriptionCONVERT 2-LANE TO 4-LANE CONVENTIONAL HIGHWAY.
Location DescriptionKERN COUNTY NEAR LOST HILLS FROM 1.0 MILE EAST OF LOST HILLS ROAD TO 0.7 MILE EAST OF ROUTE 46/5 SEPARATION
QA Service Level1 (Verified on 03/12/2018)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date10/04/2018 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing10/10/2018 Sample typeQuality Assurance
A brief description of the sample7/8 A325 Bolt Assembly The quantity of what the sample constitutes1 Lot
From where was the sample collectedDistributor First name of sampler or witnessed byScott
Last name of sampler or witnessed byLeavitt Title of samplerQA Inspector
Telephone number of sampler510 590-0116 Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameUtah Pacific Bridge
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormS28-235-18
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)TT0104413, TT0104414, TT0104415
Heat Number(s)10553610, 20495670, 10538920 Nut Mfg. Lot Number(s)28478-S-188310
Washer Mfg. Lot Number(s)D5881, 783Z30 Bolt SpecificationA325
Bolt Length(s)2-3/4, 3, 3-1/4 Nut SpecificationA563 DH
Washer SpecificationF436, F959 FinishHDG, HDG, HDG
Diameter/Size7/8, 7/8, 7/8 Bolt Mfg. Lot NumberBG1246, BG0925, BG1193
Rocap Test Requirement(s)Yes Lubricant Requirements(s)Yes
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2018-10-04-2-1ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/18/201810/18/2018
Yes
10/25/2018A325Public - Test Data Visible
2018-10-04-2-2ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/18/201810/18/2018
Yes
10/25/2018A325Public - Test Data Visible
2018-10-04-2-3ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/18/201810/18/2018
Yes
10/25/2018A325Public - Test Data Visible
2018-10-04-2-4ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/18/201810/18/2018
Yes
10/25/2018Nut Proof LoadPublic - Test Data Visible
2018-10-04-2-5ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory10/18/2018
Yes
10/25/2018Public - Test Data Visible
2018-10-04-2-6ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory10/18/2018
Yes
10/25/2018Public - Test Data Visible
2018-10-04-2-7ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory10/18/2018
Yes
10/25/2018Public - Test Data Visible
2018-10-04-2-8ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory10/18/2018
Yes
10/25/2018Public - Test Data Visible
2018-10-04-2-9ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory10/18/2018
Yes
10/25/2018Public - Test Data Visible
2018-10-04-2-10ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory10/18/2018
Yes
10/25/2018Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-10-04-2-1 ASTM F606-14a (Verified)
DIME Test ID: 2018-10-04-2-2 ASTM F606-14a (Verified)
DIME Test ID: 2018-10-04-2-3 ASTM F606-14a (Verified)
DIME Test ID: 2018-10-04-2-4 ASTM F606-14a (Verified)
DIME Test ID: 2018-10-04-2-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2018-10-04-2-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2018-10-04-2-7 ASME B1.2-83r01 (Verified)
DIME Test ID: 2018-10-04-2-8 ASME B1.2-83r01 (Verified)
DIME Test ID: 2018-10-04-2-9 ASME B1.2-83r01 (Verified)
DIME Test ID: 2018-10-04-2-10 ASME B1.2-83r01 (Verified)
DIME Test ID: 2018-10-04-2-11 ASTM B499-14 (Verified)
DIME Test ID: 2018-10-04-2-12 ASTM B499-14 (Verified)
DIME Test ID: 2018-10-04-2-13 ASTM B499-14 (Verified)
DIME Test ID: 2018-10-04-2-14 ASTM B499-14 (Verified)
DIME Test ID: 2018-10-04-2-15 ASTM B499-14 (Verified)
DIME Test ID: 2018-10-04-2-16 ASTM B499-14 (Verified)
DIME Test ID: 2018-10-04-2-17 ASTM B499-14 (Verified)
DIME Test ID: 2018-10-04-2-18 ASTM B499-14 (Verified)
DIME Test ID: 2018-10-04-2-19 ASTM B499-14 (Verified)
DIME Test ID: 2018-10-04-2-20 ASTM B499-14 (Verified)
DIME Test ID: 2018-10-04-2-21 ASTM B499-14 (Verified)
DIME Test ID: 2018-10-04-2-22 ASTM B499-14 (Verified)
DIME Test ID: 2018-10-04-2-23 ASTM E18-15 (Verified)
DIME Test ID: 2018-10-04-2-24 ASTM E18-15 (Verified)