Sample Record

Owner Lab

  • CT - Unassigned/General Field Laboratory

DIME Sample ID 2018-09-28-3

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 208945
DEA: 07288604
EFIS: 0700021080
COOP: 074663
DIST-CO-RTE-PM07-LA-710-6.0-9.4
Award Date09/02/2011
Closeout DateNot set
Work DescriptionGerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location DescriptionPort of Long Beach (District 7)
QA Service Level1 (Verified on 06/03/2013)

Sample Information

Sample Taken Date09/28/2018 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/08/2018
Sample typeIndependent Assurance A brief description of the sampleHeaded Rebar
The quantity of what the sample constitutes150 From where was the sample collectedFabricator
First name of sampler or witnessed byGary Last name of sampler or witnessed byMaComb
Title of samplerASI Telephone number of sampler5624498001
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMC Rebar Etiwanda Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL10-062-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)224018 Head Manufacturer Lot Number(s)610A
Rebar Size5 Headed Bar Model NameHRC 555
Size of HeadReduced Size - 4x Head Connection TypeForged
Head ShapeCircular Rebar ManufacturerCascade
Head ManufacturerCMC Rebar Head FabricatorCMC HRC
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2018-09-28-3-1ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/09/2018Brian
Yes
10/17/2018Bar Broke; OK Necking
2018-09-28-3-2ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/09/2018Brian
Yes
10/17/2018Bar Broke; OK Necking
2018-09-28-3-3ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/09/2018Brian
Yes
10/17/2018Bar Broke; OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-09-28-3-1 ASTM A970-15e1 (Verified)
DIME Test ID: 2018-09-28-3-2 ASTM A970-15e1 (Verified)
DIME Test ID: 2018-09-28-3-3 ASTM A970-15e1 (Verified)