Sample Record

DIME Sample ID 2018-09-10-2

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 213133
DEA: 021H9404
EFIS: 0216000158
DIST-CO-RTE-PM02-SHA-5,273-R52.1,17.1
Award Date04/05/2018
Closeout Date01/09/2019
Work DescriptionBRIDGE JOINT SEALS AND STRUCTURAL CONCRETE.
Location DescriptionSHASTA COUNTY ON ROUTE 5 AT SACRAMENTO RIVER BRIDGE OVERHEAD AND ON ROUTE 273 AT SACRAMENTO RIVER BRIDGE
QA Service Level1 (Verified on 05/23/2018)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date09/10/2018 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing09/11/2018 Sample typeQuality Assurance
A brief description of the sampleBar Lock Couplers The quantity of what the sample constitutes4
From where was the sample collectedFabricator First name of sampler or witnessed byD
Last name of sampler or witnessed byMann Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameNucor Dayton Superior
Transportation Laboratory (TL) NumberC287084 Inspector Lot Number from the Transportation Laboratory (TL) FormNA
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerDayton Superior Intermediate Assembler or FabricatorUnknown
Rebar Size5 Coupler ModelBar Lock
Coating StandardsASTM A775 epoxy Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)A150815 Rebar Heat Number(s)3500000194
Rebar Size 2 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2018-09-10-2-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory09/11/201809/11/2018
Yes
09/19/2018Service SplicePublic - Test Data Visible
2018-09-10-2-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory09/11/201809/11/2018
Yes
09/19/2018Service SplicePublic - Test Data Visible
2018-09-10-2-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory09/11/201809/11/2018
Yes
09/19/2018Service SplicePublic - Test Data Visible
2018-09-10-2-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory09/11/201809/11/2018
Yes
09/19/2018Service SplicePublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-09-10-2-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-09-10-2-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-09-10-2-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-09-10-2-4 CTM 670-December 2013 (Verified)