Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2018-09-10-2

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 213133
DEA: 021H9404
EFIS: 0216000158
DIST-CO-RTE-PM02-SHA-5,273-R52.1,17.1
Award Date04/05/2018
Closeout Date01/09/2019
Work DescriptionBRIDGE JOINT SEALS AND STRUCTURAL CONCRETE.
Location DescriptionSHASTA COUNTY ON ROUTE 5 AT SACRAMENTO RIVER BRIDGE OVERHEAD AND ON ROUTE 273 AT SACRAMENTO RIVER BRIDGE
QA Service Level1 (Verified on 05/23/2018)

Sample Information

Sample Taken Date09/10/2018 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/11/2018
Sample typeQuality Assurance A brief description of the sampleBar Lock Couplers
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byD Last name of sampler or witnessed byMann
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameNucor Dayton Superior Transportation Laboratory (TL) NumberC287084
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerDayton Superior Intermediate Assembler or FabricatorUnknown
Rebar Size5 Coupler ModelBar Lock
Coating StandardsASTM A775 epoxy Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)A150815 Rebar Heat Number(s)3500000194
Rebar Size 2 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2018-09-10-2-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory09/11/2018Brian
Yes
09/19/2018Service Splice
2018-09-10-2-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory09/11/2018Brian
Yes
09/19/2018Service Splice
2018-09-10-2-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory09/11/2018Brian
Yes
09/19/2018Service Splice
2018-09-10-2-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory09/11/2018Brian
Yes
09/19/2018Service Splice

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-09-10-2-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-09-10-2-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-09-10-2-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-09-10-2-4 CTM 670-December 2013 (Verified)