Sample Record

DIME Sample ID 2018-08-19-1

Project Information

Project IdentifiersProject ID: 213072
DEA: 023H2004
EFIS: 0217000069
DIST-CO-RTE-PM02-SHA-299-24.6/30.3
Award Date03/21/2018
Closeout Date10/05/2021
Work DescriptionCOLDPLANE EXISTING, OVERLAY WITH RHMA-O, MODIFY ELECTRICAL, GUARDRAIL.
Location DescriptionSHASTA COUNTY IN AND NEAR REDDING FROM 0.1 MILE EAST OF BOULDER DRIVE TO 0.1 MILE EAST OF HOOTENANNY LANE
QA Service Level1 (Verified on 01/08/2019)

Owner Lab

  • CT D02 - Redding Northern Regional Laboratory

Sample Information

Sample Taken Date08/19/2018 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing08/20/2018 Sample typeDepartment Acceptance
A brief description of the samplePSE 1/2 RHMA O PG64-16 The quantity of what the sample constitutesPSE 4 cans
From where was the sample collectedManufacturer First name of sampler or witnessed byCindy
Last name of sampler or witnessed byByrant Title of samplerTET
Telephone number of samplerUnknown Laboratory sample identificationD77615
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameJF Shea Fawndale
Transportation Laboratory (TL) NumberT101 C852903 Inspector Lot Number from the Transportation Laboratory (TL) FormT101 C852903
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeOGFC
HMA Grading1/2 inch Lot numberNot set
Sublot numberNot set HMA Mix NumberNot set
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set HMA PayNo

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2018-08-19-1-1AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)Terry McCormick, CT D02 - Redding Northern Regional Laboratory08/20/2018
No
Actual result is 5.80 TWM. Because correction factor is a minus -0.14, this program will not allow minus numbers to be enter.

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-08-19-1-1 AASHTO T308-10