Sample Record

DIME Sample ID 2018-08-20-3

Project Information

Project IdentifiersProject ID: 211848
DEA: 112T2174
EFIS: 1116000131
DIST-CO-RTE-PM11-SD-5-R37.4 - R46.5
Award Date12/22/2016
Closeout Date05/01/2026
Work Description(Alternative Delivery) CMGC, San Elijo Highway Bridge Replacement. Replace the San Elijo lagoon highway bridge, construct HOV lanes, construct bike and pedestrian trails and bridge, build multi-use facility at Manchester Ave.
Location DescriptionIN SAN DIEGO COUNTY IN SOLANA BEACH AND ENCINITAS FROM 0.1 MILE NORTH OF LOMAS SANTA FE DRIVE OVERCROSSING TO 0.2 MILE SOUTH OF BIRMINGHAM DRIVE OVERCROSSING
QA Service Level1 (Verified on 01/31/2017)

Owner Labs

  • CT HQ - QASI Los Angeles Field Office
  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date08/20/2018 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing08/24/2018 Sample typeQuality Assurance
A brief description of the sampleSize 18 HRC 410/490 Couplers The quantity of what the sample constitutes90
From where was the sample collectedFabricator First name of sampler or witnessed byArthur
Last name of sampler or witnessed byPeterson Title of samplerQAI
Telephone number of sampler707-342-8602 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameHRC
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL110-096-18
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerGerdau
Coupler ManufacturerNucor Intermediate Assembler or Fabricator
Rebar Size18 Coupler ModelHRC 410/490
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)M - NF100791673 F - NF1007791674 Rebar Heat Number(s)6503119002 6503119403
Rebar Size 2 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2018-08-20-3-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Glen Weldon, CT HQ - Sacramento Structural Materials Testing Laboratory08/27/2018
Yes
09/03/2018Public - Test Data Visible
2018-08-20-3-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory08/27/201808/27/2018
No
necking okay

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-08-20-3-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-08-20-3-2 CTM 670-December 2013