Sample Record
Owner Lab
- CT HQ - QASI Los Angeles Field Office
DIME Sample ID 2018-08-15-1
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 210785 DEA: 07255104 EFIS: 0700000465 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-60-R23.8/R24.5 |
| Award Date | 01/08/2016 |
| Closeout Date | 06/25/2019 |
| Work Description | CONSTRUCT WESTBOUND ONRAMP AND CONCRETE PAVEMENT |
| Location Description | LA COUNTY, IN DIMOND BAR ANDINDUSTRY AT GRAND AVENUE/SR 57/60 IC |
| QA Service Level | 1 (Verified on 02/29/2016) |
Sample Information
| Sample Taken Date | 08/15/2018 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/15/2018 |
| Sample type | Quality Assurance | A brief description of the sample | Fastener |
| The quantity of what the sample constitutes | 1 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Lorenzo | Last name of sampler or witnessed by | Garcia |
| Title of sampler | QA | Telephone number of sampler | 702 917-2503 |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Ulmer Industries | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L115-150-18 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | Nut Mfg. Lot Number(s) | 397825A | |
| Washer Mfg. Lot Number(s) | Bolt Specification | F1554 Gr. 105 | |
| Bolt Length(s) | 2' | Nut Specification | A563 |
| Washer Specification | F436 | Finish | |
| Diameter/Size | 5/8 | Bolt Mfg. Lot Number | M21826 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2018-08-15-1-1 ASME B1.2-83r01 (Verified)
DIME Test ID: 2018-08-15-1-2 ASME B1.2-83r01 (Verified)
DIME Test ID: 2018-08-15-1-3 ASME B1.2-83r01 (Verified)
DIME Test ID: 2018-08-15-1-4 ASTM B499-14 (Verified)
DIME Test ID: 2018-08-15-1-5 ASTM B499-14 (Verified)
DIME Test ID: 2018-08-15-1-6 ASTM B499-14 (Verified)
DIME Test ID: 2018-08-15-1-7 ASTM F606-14 (Verified)
DIME Test ID: 2018-08-15-1-8 ASTM F606-14a (Verified)