Sample Record

DIME Sample ID 2018-08-14-3

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 208945
DEA: 07288604
EFIS: 0700021080
COOP: 074663
DIST-CO-RTE-PM07-LA-710-6.0-9.4
Award Date09/02/2011
Closeout DateNot set
Work DescriptionGerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location DescriptionPort of Long Beach (District 7)
QA Service Level1 (Verified on 06/03/2013)

Owner Labs

  • CT HQ - QASI Los Angeles Field Office
  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date08/14/2018 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing08/14/2018 Sample typeQuality Assurance
A brief description of the sampleA449 Bolts The quantity of what the sample constitutes3
From where was the sample collectedJob Site First name of sampler or witnessed byLorenzo
Last name of sampler or witnessed byGarcia Title of samplerQA
Telephone number of sampler702 917-1503 Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameGerald Desmond Bridge
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormL115-146-18
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)L1412477
Heat Number(s)16730-10205760Z Nut Mfg. Lot Number(s)
Washer Mfg. Lot Number(s) Bolt SpecificationA490
Bolt Length(s)6" Nut SpecificationA563
Washer SpecificationF436 FinishGalvanized
Diameter/Size1.250 Bolt Mfg. Lot Number16730-10205760Z
Rocap Test Requirement(s) Lubricant Requirements(s)none
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2018-08-14-3-1ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)Glen Weldon, CT HQ - Sacramento Structural Materials Testing Laboratory08/21/2018
Yes
08/28/2018FAILS RetestPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-08-14-3-1 ASTM F606-14a (Verified)