Sample Record

DIME Sample ID 2018-08-13-5

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 213153
DEA: 044S7804
EFIS: 0400020145
DIST-CO-RTE-PM04-MRN-1-24.7
Award Date04/26/2018
Closeout Date10/17/2019
Work DescriptionREPLACE EXISTING CULVERTS WITH 36' REINFORCED CONCRETE SLAB BRIDGE.
Location DescriptionMARIN COUNTY NEAR OLEMA AT 1.8 MILES SOUTH OF SIR FRANCIS DRAKE BOULEVARD
QA Service Level1 (Verified on 06/12/2018)

Owner Lab

  • CT SC - 3672 - Fairfield

Sample Information

Sample Taken Date08/13/2018 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing08/15/2018 Sample typeQuality Assurance
A brief description of the samplecoupler nunber 4 The quantity of what the sample constitutes4
From where was the sample collectedJob Site First name of sampler or witnessed byJanine
Last name of sampler or witnessed byMarr Title of samplerSR
Telephone number of sampler510-385-6764 Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameHarris Rebar
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerDextra America
Coupler ManufacturerBartec Intermediate Assembler or FabricatorHarris rebar
Rebar Size4 Coupler Modelnumber 4
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)B4HMC01AAT2 Rebar Heat Number(s)DL12102189
Rebar Size 2 4 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2018-08-13-5-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory08/17/201808/17/2018
Yes
08/24/2018Service SplicePublic - Test Data Visible
2018-08-13-5-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory08/17/201808/17/2018
Yes
08/24/2018Service SplicePublic - Test Data Visible
2018-08-13-5-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory08/17/201808/17/2018
Yes
08/24/2018Service SplicePublic - Test Data Visible
2018-08-13-5-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory08/17/201808/17/2018
Yes
08/24/2018Service SplicePublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-08-13-5-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-08-13-5-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-08-13-5-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-08-13-5-5 CTM 670-December 2013 (Verified)