Sample Record
Owner Labs
- CT HQ - QASI Los Angeles Field Office
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2018-08-09-1
Project Information
| Project Identifiers | Project ID: 212562 DEA: 024G5504 EFIS: 0214000036 |
|---|---|
| DIST-CO-RTE-PM | 02-SIS-5-2.7/R11.4 |
| Award Date | 03/12/2018 |
| Closeout Date | 10/05/2020 |
| Work Description | RECONSTRUCT WITH HMA AND PCC, WIDEN STRUCTURE AND UPGRADE RAILS |
| Location Description | SISKIYOU COUNTY IN AND NEAR DUNSMUIR FROM SACRAMENTO RIVER BRIDGE TO 0.6 MILE SOUTH OF NORTH MOUNT SHASTA UNDERPASS |
| QA Service Level | 1 (Verified on 04/04/2018) |
Sample Information
| Sample Taken Date | 08/09/2018 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 08/09/2018 |
| Sample type | Quality Assurance | A brief description of the sample | Retest ASTM A934 |
| The quantity of what the sample constitutes | 357 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Sherri | Last name of sampler or witnessed by | Brannon |
| Title of sampler | QA Inspector | Telephone number of sampler | 7077918219 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | JC Supply Manufacturing | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L48-080-18 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM7 - Epoxy Coated Rebar | Rebar Heat Number(s) | 4076159 |
|---|---|---|---|
| Rebar Epoxy Batch Number(s) | 8496027156, 8596027332 | Rebar Coating Specification | ASTM A934 |
| Rebar Size (#) | 6 | Rebar Coating Color | Purple |
| Rebar Manufacturer | CMC | Rebar Coater | JC Supply And Manufacturing |
| Rebar Powder Manufacturer | Valspar | Release Number | |
| Quality Assurance Code |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2018-08-09-1-1 ASTM A934-13 (Verified)
DIME Test ID: 2018-08-09-1-2 ASTM A934-13 (Verified)
DIME Test ID: 2018-08-09-1-3 ASTM A934-13 (Verified)