Sample Record
DIME Sample ID 2026-10-12-2
Project Information
| Project Identifiers | Project ID: 994675 DEA: 07390204 EFIS: 0722000334 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-47-0.4 / 2.1 |
| Award Date | 01/24/2025 |
| Closeout Date | Not set |
| Work Description | Bridge deck replacement with lightweight precast deck panels ultra high performance concrete. Also includes: replacement of seismic sensors, upgrades to median barrier, railings, fences and guard rails. New finger joints. |
| Location Description | RTE 47 between Terminal Island and San Pedro PM 0.4/2.1 |
| QA Service Level | 1 (Verified on 08/07/2023) |
Owner Lab
- CT HQ - QASI Los Angeles Field Office
Sample Information
| Sample Taken Date | 10/12/2026 | Sample Unique Key | 2 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/19/2026 | Sample type | Quality Assurance |
| A brief description of the sample | 7/8" x 2.25" F3125/F1852 A325TC Bolt Assembly | The quantity of what the sample constitutes | 5130 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Jayce |
| Last name of sampler or witnessed by | Groves | Title of sampler | Quailty Assurance Inspector |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Unytite Inc | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 44484-11020200 |
|---|---|---|---|
| Bolt Heat Number | 11020200 | Nut Heat Number | 5807144503 |
| Washer Heat Number | A83589 | Nut Mfg. Lot Number(s) | N0385-5807144503 |
| Washer Mfg. Lot Number(s) | 1-060726 | Bolt Specification | ASTM F3125 Grade F1852 |
| Bolt Length(s) | 2-1/4" | Nut Specification | ASTM A563 Grade DH |
| Washer Specification | ASTM F436 Type 1 | Bolt Galvanization | Mechanically Galvanized |
| Nut Galvanization | Mechanically Galvanized | Washer Galvanization | Mechanically Galvanized |
| Bolt Diameter | 7/8" | Nut Diameter | 7/8" |
| Washer Diameter | 7/8" | Bolt Mfg. Lot Number | 44484-11020200 |
| Rocap Test Requirement(s) | ASTM F3125 | Lubricant Requirements(s) | |
| Washer Inner Diameter(s) | Bolt Mill Supplier | Charter Steel | |
| Nut Mill Supplier | Gerdau | Washer Mill Supplier | Cleveland-Cliffs |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| 2026-10-12-2-1 | ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter) | Jereme Morgan, CT HQ - Sacramento Structural Materials Testing Laboratory | 10/19/2026 | 10/19/2026 | No | ||||
| 2026-10-12-2-2 | ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter) | Jereme Morgan, CT HQ - Sacramento Structural Materials Testing Laboratory | 10/19/2026 | 10/19/2026 | No | ||||
| 2026-10-12-2-3 | ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter) | Jereme Morgan, CT HQ - Sacramento Structural Materials Testing Laboratory | 10/19/2026 | 10/19/2026 | No | ||||
| 2026-10-12-2-4 | ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter) | Jereme Morgan, CT HQ - Sacramento Structural Materials Testing Laboratory | 10/19/2026 | 10/19/2026 | No |
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2026-10-12-2-1 ASME B1.2-83r17
DIME Test ID: 2026-10-12-2-2 ASME B1.2-83r17
DIME Test ID: 2026-10-12-2-3 ASME B1.2-83r17
DIME Test ID: 2026-10-12-2-4 ASME B1.2-83r17