Sample Record

DIME Sample ID 2026-09-23-1

Project Information

Project IdentifiersProject ID: 1000710
DEA: 100P9244
EFIS: 1023000226
DIST-CO-RTE-PM10-MPA-140-42.0/42.7
Award Date08/22/2025
Closeout DateNot set
Work DescriptionFergusen Slide Rock Avalanche Shed
Location DescriptionMariposa County, along Route 140 in the Merced River canyon, about 8 miles east of Briceburg and 7.6 miles west of El Portal.
QA Service Level1 (Verified on 10/15/2024)

Owner Labs

  • CT HQ - Sacramento Structural Materials Testing Laboratory
  • CT HQ - QASI Bay Area Field Office

Sample Information

Sample Taken Date09/23/2026 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing09/30/2026 Sample typeQuality Assurance
A brief description of the sample4 EA 5ft long epoxy coated strand samples from each spool per SS Section 50-1.01C(5) The quantity of what the sample constitutes7
From where was the sample collectedManufacturer First name of sampler or witnessed byEdward
Last name of sampler or witnessed byLeach Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameSumiden
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Sample Location

Latitude 38.555993 Longitude -121.434041 Open in Google Maps

Material Information

Material TypeSMTL TM4 - Prestressing Strand Comments
Reel/Coil/Pack Number(s)T301055-8-1, T301057-6-1, T301057-7-1,T350163-1-1, T350163-4-1, T350417-7-1, T350419-8-3 Number of Coils
Group Number Strand Diameter.6 in
Grade270 Strand SpecificationASTM A 882
Heat Number(s)T0243142, T0253276, T1382180 Mfg. Lot Number(s)n/a
Manufacturer(s)Sumiden

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-09-23-1-1ASTM A882-20: Standard Specification for Filled Epoxy-Coated Seven-Wire Prestressing Steel Strand (Withdrawn 2019) (Coating Adhesion)Andrew Auvinen, CT HQ - Sacramento Structural Materials Testing Laboratory10/06/202610/06/2026
Yes
10/07/2026T301055-8-1Public - Test Data Visible
2026-09-23-1-2ASTM A882-20: Standard Specification for Filled Epoxy-Coated Seven-Wire Prestressing Steel Strand (Withdrawn 2019) (Coating Adhesion)Andrew Auvinen, CT HQ - Sacramento Structural Materials Testing Laboratory10/06/202610/06/2026
Yes
10/07/2026T301057-6-1Public - Test Data Visible
2026-09-23-1-3ASTM A882-20: Standard Specification for Filled Epoxy-Coated Seven-Wire Prestressing Steel Strand (Withdrawn 2019) (Coating Adhesion)Andrew Auvinen, CT HQ - Sacramento Structural Materials Testing Laboratory10/06/202610/06/2026
Yes
10/07/2026T301057-7-1Public - Test Data Visible
2026-09-23-1-4ASTM A882-20: Standard Specification for Filled Epoxy-Coated Seven-Wire Prestressing Steel Strand (Withdrawn 2019) (Coating Adhesion)Andrew Auvinen, CT HQ - Sacramento Structural Materials Testing Laboratory10/06/202610/06/2026
Yes
10/07/2026T350163-1-1Public - Test Data Visible
2026-09-23-1-5ASTM A882-20: Standard Specification for Filled Epoxy-Coated Seven-Wire Prestressing Steel Strand (Withdrawn 2019) (Coating Adhesion)Andrew Auvinen, CT HQ - Sacramento Structural Materials Testing Laboratory10/06/202610/06/2026
Yes
10/07/2026T350163-4-1Public - Test Data Visible
2026-09-23-1-6ASTM A882-20: Standard Specification for Filled Epoxy-Coated Seven-Wire Prestressing Steel Strand (Withdrawn 2019) (Coating Adhesion)Andrew Auvinen, CT HQ - Sacramento Structural Materials Testing Laboratory10/06/202610/06/2026
Yes
10/07/2026T350417-7-1Public - Test Data Visible
2026-09-23-1-7ASTM A882-20: Standard Specification for Filled Epoxy-Coated Seven-Wire Prestressing Steel Strand (Withdrawn 2019) (Coating Adhesion)Andrew Auvinen, CT HQ - Sacramento Structural Materials Testing Laboratory10/06/202610/06/2026
Yes
10/07/2026T350419-8-3Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2026-09-23-1-1 ASTM A882-20 (Verified)
DIME Test ID: 2026-09-23-1-2 ASTM A882-20 (Verified)
DIME Test ID: 2026-09-23-1-3 ASTM A882-20 (Verified)
DIME Test ID: 2026-09-23-1-4 ASTM A882-20 (Verified)
DIME Test ID: 2026-09-23-1-5 ASTM A882-20 (Verified)
DIME Test ID: 2026-09-23-1-6 ASTM A882-20 (Verified)
DIME Test ID: 2026-09-23-1-7 ASTM A882-20 (Verified)