Sample Record

DIME Sample ID 2018-05-14-3

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 212743
DEA: 030H26U4
EFIS: 0317000247
DIST-CO-RTE-PM03-PLA-65-R5.0/R6.6
Award Date02/14/2018
Closeout Date10/21/2022
Work DescriptionNORTHBOUND WIDENING AND RAMP IMPROVEMENTS.
Location DescriptionPLACER COUNTY IN AND NEAR ROSEVILLE AND ROCKLIN FROM 0.1 MILE SOUTH OF EAST ROSEVILLE VIADUCT TO 0.5 MILE SOUTH OF PLEASANT GROVE BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 12/18/2017)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date05/14/2018 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing05/15/2018 Sample typeQuality Assurance
A brief description of the sample size 7 flash welded hoops The quantity of what the sample constitutes150
From where was the sample collectedFabricator First name of sampler or witnessed byJames
Last name of sampler or witnessed byDoe Title of samplerQA Inspector
Telephone number of sampler(510) 918-4918 Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameCMC Rebar Tracy CA
Transportation Laboratory (TL) NumberC836244 Inspector Lot Number from the Transportation Laboratory (TL) FormB358-044-18
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4074933
Hoop Manufacturer Lot Number(s) 5, 111H Material Standard CodeASTM A706
Material Grade60 Rebar Size7
Diameter of Hoop10'-0" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC
Welding CompanyCMC Rebar (Tracy) Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2018-05-14-3-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory05/15/201805/15/2018
Yes
05/23/2018Bar Broke; OK NeckingPublic - Test Data Visible
2018-05-14-3-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory05/15/201805/15/2018
Yes
05/23/2018Bar Broke; OK NeckingPublic - Test Data Visible
2018-05-14-3-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory05/15/201805/15/2018
Yes
05/23/2018Bar Broke; OK NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-05-14-3-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-05-14-3-2 CTM 670-December 2013 (Verified)