Sample Record

DIME Sample ID 2018-04-27-10

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210735
DEA: 071193U4
EFIS: 0713000007
DIST-CO-RTE-PM07-LA-10-37.2/42.4
Award Date11/16/2015
Closeout Date07/11/2022
Work DescriptionCONSTRUCT HOV LANES, WIDEN BRIDGES, AND REALIGN RAMPS.
Location DescriptionIN LA COUNTY FROM CITRUS STREET IN WEST COVINA TO ROUTE 57 IN POMONA
QA Service Level1 (Verified on 03/07/2016)

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

Sample Information

Sample Taken Date04/27/2018 Sample Unique Key10
Date that the sample was received by the laboratory/organization performing the testing05/04/2018 Sample typeQuality Assurance
A brief description of the sample6x12 The quantity of what the sample constitutes2
From where was the sample collectedJob Site First name of sampler or witnessed bySAUL
Last name of sampler or witnessed byFIERRO Title of samplerASR
Telephone number of samplerUnknown Laboratory sample identification946-28
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameNOT PROVIDED
Transportation Laboratory (TL) Number2289028 Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierRW 2138 STEM WALL Structure nameRW 2138 STEM WALL
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberCM5645
The truck number from where the sample was collected655 The batch plant ticket number from where the sample was collected2289028
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedLOAD 5 Where the material sample would have been placed if not sampledRW 2138 STEM WALL
From Lot No.Unknown Bag Lot No.Unknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2018-04-27-10-1ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMM, CT D08 - Fontana Southern Regional Laboratory05/25/2018
Yes
06/01/2018Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-04-27-10-1 ASTM C39-17a (Verified)