Sample Record

DIME Sample ID 2026-08-20-3

Project Information

Project IdentifiersProject ID: 1002077
DEA: 033H5904
EFIS: 0318000017
DIST-CO-RTE-PM03-PLA-80-R26.3/R55.2
Award Date01/08/2026
Closeout DateNot set
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 04/07/2026)

Owner Labs

  • CT HQ - Sacramento Structural Materials Testing Laboratory
  • CT HQ - QASI Bay Area Field Office

Sample Information

Sample Taken Date08/20/2026 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing08/21/2026 Sample typeVerification
A brief description of the sampleA775 1.5 dowel bar The quantity of what the sample constitutes40,800 LBS
From where was the sample collectedFabricator First name of sampler or witnessed bySherri
Last name of sampler or witnessed byBrannon Title of samplerQuality Assurance Inspector
Telephone number of sampler9168266371 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameAmerican Highway - Simplex
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormB22-047-26
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM7 - Epoxy Coated Dowels Dowel Metal Heat Number1201079257
Dowel Epoxy Batch NumberCH1466HH Dowel Coating SpecificationASTM A775
Dowel Size1.5 in Dowel Coating ColorGreen
Dowel ManufacturerNucor Dowel CoaterAmerican Highway Simplex
Release Number Quality Assurance Code
Rebar Size (#)

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-08-20-3-1ASTM A775-19: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)Andrew Auvinen, CT HQ - Sacramento Structural Materials Testing Laboratory08/31/202608/31/2026
Yes
09/01/2026Public - Test Data Visible
2026-08-20-3-2ASTM A775-19: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)Andrew Auvinen, CT HQ - Sacramento Structural Materials Testing Laboratory08/31/202608/31/2026
Yes
09/01/2026Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
M0825-1833 Dime Number 2026-08-20-3pdf08/31/2026   Info

Test File Attachments


DIME Test ID: 2026-08-20-3-1 ASTM A775-19 (Verified)
DIME Test ID: 2026-08-20-3-2 ASTM A775-19 (Verified)