Sample Record

DIME Sample ID 2026-06-02-125

Project Information

Project IdentifiersProject ID: 993595
DEA: 042Q5504
EFIS: 0419000024
DIST-CO-RTE-PM04-SOL-12-7.9/14.1
Award Date02/14/2025
Closeout DateNot set
Work DescriptionRHMA OVERLAY, REPLACE CULVERTS, BRIDGE RAILS, AND MEDIAN BARRIERS.
Location DescriptionSOLANO COUNTY NEAR SUISUN CITY FROM 0.2 MILE EAST OF LAWLER RANCH PARKWAY TO 0.5 MILE EAST OF SHILOH ROAD
QA Service Level1 (Verified on 02/22/2022)

Owner Lab

  • CT D04 - Hayward DME / District Laboratory

Sample Information

Sample Taken Date06/02/2026 Sample Unique Key125
Date that the sample was received by the laboratory/organization performing the testing06/26/2026 Sample typeProduction Start-Up
A brief description of the sample1/2" RHMA-G The quantity of what the sample constitutes20 BOXES OF RHMA
From where was the sample collectedManufacturer First name of sampler or witnessed byAbel
Last name of sampler or witnessed byHuerta Title of sampler
Telephone number of sampler Laboratory sample identificationD04-SE-26-019
Linked DIME Sample ID The fabricator/manufacturer/facility nameTeichert Woodland Batch Plant
Transportation Laboratory (TL) NumberCON-060226-1 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number1
Sublot number1 HMA Mix Number306 40542508 V
Binder content (%)7.5 Virgin binder PGPG 64-16
Design binder PG Binder Supplier
RAP content (%)Not set WMA Additives
Antistrip type

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-06-02-125-1AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)Nicholas Shelly - BSK, CT D04 - Hayward DME / District Laboratory07/08/202608/13/2026
No
Average Bulk Specific Gravity= 2.280
2026-06-02-125-2AASHTO T269-24E25: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)Nicholas Shelly - BSK, CT D04 - Hayward DME / District Laboratory07/08/202608/13/2026
No
Gmm=2.411, Average Percent Air Voids= 5.5%

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2026-06-02-125-1 AASHTO T275-07r12
DIME Test ID: 2026-06-02-125-2 AASHTO T269-24E25