Sample Record

Owner Lab

  • CT D04 - Hayward DME / District Laboratory

DIME Sample ID 2026-05-12-75

Project Information

Project IdentifiersProject ID: 1001683
DEA: 040AA194
EFIS: 0419000450
DIST-CO-RTE-PM04-CC-4-R29.0/R44.4
Award Date01/09/2026
Closeout DateNot set
Work DescriptionCOLD PLANE AC PVMT, RHMA-G & HMA OVERLAY, REPLACE AC SURF, & MGS.
Location DescriptionCONTRA COSTA COUNTY IN ANTIOCH AND AT BYRON FROM HILLCREST AVENUE OVERCROSSING TO BYRON HIGHWAY
QA Service Level1 (Verified on 10/06/2025)

Sample Information

Sample Taken Date05/12/2026 Sample Unique Key75
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing06/18/2026
Sample typeProduction Start-Up A brief description of the sample1/2" HMA-A + 25% RAP
The quantity of what the sample constitutes16 Boxes HMA From where was the sample collectedManufacturer
First name of sampler or witnessed byCody Last name of sampler or witnessed byCordero
Title of sampler Telephone number of sampler
Laboratory sample identificationD04-SE-26-016 Linked DIME Sample ID
The fabricator/manufacturer/facility nameTeichert Materials Vernalis Transportation Laboratory (TL) NumberCON-051226-1
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number302 40442436 P
Binder content (%)0.0 Virgin binder PG
Design binder PG Binder Supplier
RAP content (%)25 WMA Additives
Antistrip type

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-05-12-75-1AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)M. Paulson - Kleinfelder-Hayward, CT D04 - Hayward DME / District Laboratory06/25/202608/12/2026
No
Average Bulk Specific Gravity= 2.380  
2026-05-12-75-2AASHTO T269-24E25: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)M. Paulson - Kleinfelder-Hayward, CT D04 - Hayward DME / District Laboratory06/25/202608/12/2026
No
Gmm=2.457, Average Percent Air Voids= 3.1%  
2026-05-12-75-3AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)Bryce ONeil - Kleinfelder-Hayward, CT D04 - Hayward DME / District Laboratory06/26/202608/12/2026
No
Wet= 191psi, Dry= 269psi, TSR= 71%  
2026-05-12-75-4CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix AsphaltM. Paulson - Kleinfelder-Hayward, CT D04 - Hayward DME / District Laboratory06/25/202608/12/2026
No
H.W. > 15,000 passes, SIP > 15,000 passes  

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2026-05-12-75-1 AASHTO T275-07r12
DIME Test ID: 2026-05-12-75-2 AASHTO T269-24E25
DIME Test ID: 2026-05-12-75-3 AASHTO T283-14
DIME Test ID: 2026-05-12-75-4 CTM 389-19