Sample Record

DIME Sample ID 2018-04-18-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210808
DEA: 020E0904
EFIS: 0200000016
DIST-CO-RTE-PM02-SHA-5-R29.3/R31.1,R45.0/R45.8
Award Date02/03/2016
Closeout Date10/21/2020
Work DescriptionREPLACE BRIDGE, REALIGN ROADWAY AND SEISMIC RETROFIT
Location DescriptionIN SHASTA COUNTY ABT 8 MI N OF SHASTA LAKE CTY AND NEAR LAKEHEAD FRM TURNTABLE BAY O/C TO 0.1 MI N OF O'BRIEN SRRA & FRM 0.4 MI S TO 0.3 MI N OF DOG CREEK BRIDGE.
QA Service Level1 (Verified on 09/23/2015)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date04/18/2018 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing04/18/2018 Sample typeRetest
A brief description of the sample Couplers The quantity of what the sample constitutes4
From where was the sample collectedJob Site First name of sampler or witnessed byGlen
Last name of sampler or witnessed byLawson Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameHarris Rebar
Transportation Laboratory (TL) NumberC340590 Inspector Lot Number from the Transportation Laboratory (TL) FormB362-018-18
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingRetest
Service or UltimateService Material Standard CodeASTM A955
Material Grade75 Rebar ManufacturerHarris Rebar
Coupler ManufacturerHarris Rebar Intermediate Assembler or FabricatorUnknown
Rebar Size8 Coupler ModelThreaded stainless Coupler
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s) M9P1 Rebar Heat Number(s)34R1
Rebar Size 2 Not set Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2018-04-18-1-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory04/19/201804/19/2018
Yes
04/30/2018Service SplicePublic - Test Data Visible
2018-04-18-1-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory04/19/201804/19/2018
Yes
04/30/2018Service SplicePublic - Test Data Visible
2018-04-18-1-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory04/19/201804/19/2018
Yes
04/30/2018Service SplicePublic - Test Data Visible
2018-04-18-1-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory04/19/201804/19/2018
Yes
04/30/2018Service SplicePublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-04-18-1-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-04-18-1-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-04-18-1-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-04-18-1-4 CTM 670-December 2013 (Verified)