Sample Record

Owner Lab

  • CT D02 - Redding Northern Regional Laboratory

DIME Sample ID 2026-07-07-92

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 1000697
DEA: 021J75U4
EFIS: 0224000092
DIST-CO-RTE-PM02-LAS-36-14.4/R16.8
Award Date01/23/2025
Closeout DateNot set
Work DescriptionPLACE HMA AND CLASS 2 AB, EXCAVATE ROADWAY, & INSTALL LIGHTING SYSTEM.
Location DescriptionLASSEN COUNTY ABOUT 9 MILES WEST OF SUSANVILLE FROM 1.3 MILES WEST TO 1.2 MILES EAST OF WILLARD CREEK ROAD
QA Service Level1 (Verified on 10/24/2024)

Sample Information

Sample Taken Date07/07/2026 Sample Unique Key92
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/08/2026
Sample typeAcceptance A brief description of the sample1 Bag Subgrade
The quantity of what the sample constitutesExisting Subgrade From where was the sample collectedJob Site
First name of sampler or witnessed byDave Last name of sampler or witnessed byLockett
Title of samplerConsultant Telephone number of sampler
Laboratory sample identificationD80263 Linked DIME Sample ID
The fabricator/manufacturer/facility nameHat Creek Construction Transportation Laboratory (TL) Number895427
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedSta.857+98 10' L of CL
Where the material sample would have been placed if not sampled

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-07-07-92-1CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesJosh Murphy , CT D02 - Redding Northern Regional Laboratory07/16/202607/16/2026
Yes
07/16/2026 
2026-07-07-92-2CTM 301-March 2000: Method for Determining the Resistance "R" Value of Treated and Untreated Bases, Subbases, and Basement Soils by the StabilometerJosh Murphy , CT D02 - Redding Northern Regional Laboratory07/16/202607/16/2026
Yes
07/16/2026R-Val is approx. Press had to be stopped prematurely. 

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2026-07-07-92-1 CTM 202-November 2011 (Verified)
DIME Test ID: 2026-07-07-92-2 CTM 301-March 2000 (Verified)