Sample Record
DIME Sample ID 2026-07-09-1
Project Information
| Project Identifiers | Project ID: 1002145 DEA: 010A1114 EFIS: 0116000148 |
|---|---|
| DIST-CO-RTE-PM | 01-HUM-101-R53.7/M54.2 |
| Award Date | 01/20/2026 |
| Closeout Date | Not set |
| Work Description | South Fork Eel River Bridge Seismic |
| Location Description | NEAR RIO DELL FROM 0.2 MILE SOUTH OF EEL RIVER BRIDGE TO 0.4 MILE SOUTH OF METROPOLITAN HEIGHTS ROAD |
| QA Service Level | 1 (Verified on 04/22/2026) |
Owner Labs
- CT HQ - QASI Los Angeles Field Office
- CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Information
| Sample Taken Date | 07/09/2026 | Sample Unique Key | 1 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/13/2026 | Sample type | Quality Assurance |
| A brief description of the sample | #8 6'-2" diameter welded hoops | The quantity of what the sample constitutes | 580 hoops |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Jacob |
| Last name of sampler or witnessed by | Garcia | Title of sampler | Quality Assurance Inspector |
| Telephone number of sampler | 7606866753 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | CMC Rebar San Bernardino | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L169-095-26 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 9014144 |
| Hoop Manufacturer Lot Number(s) | 1-4. Samples taken from lots 1 & 3 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | #8 |
| Diameter of Hoop | 6'-2" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | CMC Steel Arizona |
| Welding Company | CMC Rebar San Bernardino | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Submitted Tests
Test File Attachments
DIME Test ID: 2026-07-09-1-1 CTM 670-December 2013 (Verified)