Sample Record

Owner Labs

  • CT SC - 3672 - Richmond
  • CT HQ - Vallejo Field Laboratory

DIME Sample ID 2026-07-08-10

Project Information

Project IdentifiersProject ID: 1001075
DEA: 040W0304
EFIS: 0420000164
DIST-CO-RTE-PM04-ALA-580-0.02/6.3
Award Date10/16/2025
Closeout DateNot set
Work DescriptionReplace existing tolling structure with open road tolling (ORT) system at the Richmond-San Rafael.
Location DescriptionNot set
QA Service Level1 (Verified on 03/13/2025)

Sample Information

Sample Taken Date07/08/2026 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing06/29/2026
Sample typeQuality Assurance A brief description of the sample60" CIDH
The quantity of what the sample constitutes18 CY From where was the sample collectedJob Site
First name of sampler or witnessed byEric Last name of sampler or witnessed byRacadag
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCemex Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number1617357
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected1
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedNear Marina Bay exit WB in Richmond Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-07-08-10-1ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMario Periera Vaz, CT HQ - Vallejo Field Laboratory07/15/202607/15/2026
Yes
07/15/2026Public - Test Data Visible
2026-07-08-10-2ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensDaniel Arreola, CT HQ - Vallejo Field Laboratory07/22/202607/22/2026
Yes
07/22/2026Public - Test Data Visible
2026-07-08-10-3ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensYannick Aranas, CT HQ - Vallejo Field Laboratory08/05/202608/05/2026
Yes
08/05/2026Cylinders reached strength of 7,350 & 7,320 psi. Did not break cylinders as lab is certified for 7,000 psi with unbonded caps. Did not test 3rd cylinderPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2026-07-08-10-1 ASTM C39-21 (Verified)
DIME Test ID: 2026-07-08-10-2 ASTM C39-21 (Verified)
DIME Test ID: 2026-07-08-10-3 ASTM C39-21 (Verified)