Sample Record

Owner Labs

  • CT HQ - QASI Los Angeles Field Office
  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2026-06-26-5

Project Information

Project IdentifiersProject ID: 994418
DEA: 040J5504
EFIS: 0414000012
DIST-CO-RTE-PM04-ALA-84-17.2/17.2
Award Date02/03/2026
Closeout DateNot set
Work DescriptionREPLACE BRIDGE, WIDEN ROADWAY, & CONSTRUCT SIDEWALKS.
Location DescriptionALAMEDA COUNTY AT SUNOL FROM SILVER SPRING ROAD UNDERPASS TO PLEASANTON SUNOL ROAD
QA Service Level1 (Verified on 12/01/2022)

Sample Information

Sample Taken Date06/26/2026 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing07/01/2026
Sample typeQuality Assurance A brief description of the sample#8x6'-2"
The quantity of what the sample constitutes57 of 317 From where was the sample collectedFabricator
First name of sampler or witnessed byJohnathan Last name of sampler or witnessed byShoulders
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTNT Rebar Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)1201077220
Hoop Manufacturer Lot Number(s)Lot 3 Material Standard CodeASTM A706
Material Grade60 Rebar Size#8
Diameter of Hoop6'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-06-26-5-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory07/14/202607/14/2026
Yes
07/14/2026 

Sample File Attachments

File NameExtensionDate UploadedActions
26001338.005A_20260626_26-SAC-01040_Metal_DIME ID#2026-06-26-5pdf07/10/2026   Info
COVER SHEET TM5 Welded Hoops rev 2026-06-26-5pdf07/10/2026   Info

Test File Attachments


DIME Test ID: 2026-06-26-5-1 CTM 670-December 2013 (Verified)