DIME Sample ID 2026-06-25-28

Project Information

Project IdentifiersProject ID: 995204
DEA: 07325804
EFIS: 0716000090
DIST-CO-RTE-PM07-LA-1-18.0/33.3
Award DateNot set
Closeout DateNot set
Work DescriptionCOLD PLANE AND OVERLAY ASPHALT CONCRETE PAVEMENT, INSTALL CURB RAMPS.
Location DescriptionLOS ANGELES COUNTY AT VARIOUS LOCATIONS ON ROUTE 1 FROM PASEO DE LAS DELICIAS TO DEWEY STREET
QA Service Level1 (Verified on 10/19/2023)

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

Sample Information

Sample Taken Date06/25/2026 Sample Unique Key28
Date that the sample was received by the laboratory/organization performing the testing08/06/2026 Sample typeQuality Assurance
A brief description of the sample3" x 60" Double End Studs The quantity of what the sample constitutes49
From where was the sample collectedSource First name of sampler or witnessed byJayce
Last name of sampler or witnessed byGroves Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameHalo
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)No
Heat Number(s)256622, A244893, 140694, 190155263 Nut Mfg. Lot Number(s)BZHN
Washer Mfg. Lot Number(s)S3323675 Bolt SpecificationF1554
Bolt Length(s)60" Nut SpecificationA563
Washer SpecificationF436 FinishGalvanized
Diameter/Size3 Bolt Mfg. Lot Number256622
Rocap Test Requirement(s)No Lubricant Requirements(s)No
Washer Inner Diameter(s)three inches and one eighth Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-06-25-28-1ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)Jereme Morgan, CT HQ - Sacramento Structural Materials Testing Laboratory08/07/202608/07/2026
No

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2026-06-25-28-1 ASME B1.2-83r17