Sample Record
Owner Lab
- CT HQ - QASI Bay Area Field Office
DIME Sample ID 2026-06-25-21
Project Information
| Project Identifiers | Project ID: 993812 DEA: 11431274 EFIS: 1121000129 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-5-R0.3/R36.0 |
| Award Date | 01/28/2025 |
| Closeout Date | Not set |
| Work Description | CMGC Project- Restore the pavement to a state of good repair through roadway rehabilitation, pavement preservation, drainage restoration, transportation management system upgrades, and American with Disabilities Act (ADA) infrastructure improvements. |
| Location Description | SD County |
| QA Service Level | 1 (Verified on 09/19/2022) |
Sample Information
| Sample Taken Date | 06/25/2026 | Sample Unique Key | 21 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/07/2026 |
| Sample type | Quality Assurance | A brief description of the sample | A325 |
| The quantity of what the sample constitutes | 70 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Carpender |
| Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | (415) 608-1742 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Universal Industrial Sales, Inc | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B24-210-26 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | na |
|---|---|---|---|
| Heat Number(s) | L881P1 | Nut Mfg. Lot Number(s) | na |
| Washer Mfg. Lot Number(s) | na | Bolt Specification | A325 |
| Bolt Length(s) | 4-1/2" | Nut Specification | na |
| Washer Specification | na | Finish | MG |
| Diameter/Size | 1-1/4" | Bolt Mfg. Lot Number | M5412-1 |
| Rocap Test Requirement(s) | na | Lubricant Requirements(s) | na |
| Washer Inner Diameter(s) | na |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| 2026-06-25-21-1 | ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter) | Jereme Morgan, CT HQ - Sacramento Structural Materials Testing Laboratory | 07/07/2026 | 07/07/2026 | No | ||||
| 2026-06-25-21-2 | ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter) | Jereme Morgan, CT HQ - Sacramento Structural Materials Testing Laboratory | 07/07/2026 | 07/07/2026 | No |
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2026-06-25-21-1 ASME B1.2-83r17
DIME Test ID: 2026-06-25-21-2 ASME B1.2-83r17