Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2026-05-18-69

Project Information

Project IdentifiersProject ID: 1001361
DEA: 120M9704
EFIS: 1213000099
DIST-CO-RTE-PM12-ORA-57-11.5/12.5
Award Date09/25/2025
Closeout DateNot set
Work DescriptionCONST BRIDGES, RET WALLS, JPCP, HMA, CONC BARRIERS AND ELECT SYSTEMS.
Location DescriptionORANGE COUNTY IN ORANGE AND ANAHEIM FROM 0.2 MILE SOUTH OF ORANGEWOOD AVENUE UNDERCROSSING TO KATELLA AVENUE UNDERCROSSING
QA Service Level1 (Verified on 07/28/2025)

Sample Information

Sample Taken Date05/18/2026 Sample Unique Key69
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing06/17/2026
Sample typeQuality Assurance A brief description of the sampleHRC 500/510 coupler
The quantity of what the sample constitutes135 From where was the sample collectedManufacturer
First name of sampler or witnessed byKent Last name of sampler or witnessed byAllen
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHRC Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerVintage Steel LLC
Coupler ManufacturerHRC Intermediate Assembler or Fabricator
Rebar Size#11 Coupler ModelHRC 500/510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)73142156, 73140308 Rebar Heat Number(s)2320449
Rebar Size 2 Coupler Unique IDTP-17-03

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-05-18-69-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory06/19/202606/19/2026
Yes
06/19/2026 

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2026-05-18-69-1 CTM 670-December 2013 (Verified)