Sample Record

DIME Sample ID 2018-02-15-9

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 212521
DEA: 043S9104
EFIS: 0400001044
DIST-CO-RTE-PM04-MRN-1-7.7/7.8
Award Date08/09/2017
Closeout Date09/19/2018
Work DescriptionCONSTRUCT SOLDIER PILE WALL
Location DescriptionMARIN COUNTY NEAR MUIR BEACH AT 0.2 MILE NORTH OF COLD STREAMFIRE ROAD.
QA Service Level1 (Verified on 07/17/2017)

Owner Labs

  • CT SC - 3672 - Fairfield
  • CT HQ - Sacramento Concrete Testing Laboratory

Sample Information

Sample Taken Date02/15/2018 Sample Unique Key9
Date that the sample was received by the laboratory/organization performing the testing03/06/2018 Sample typeQuality Assurance
A brief description of the sampleconc sample The quantity of what the sample constitutes2 6x12 concrete cylinders
From where was the sample collectedJob Site First name of sampler or witnessed byJeremy
Last name of sampler or witnessed byLight Title of samplerASR
Telephone number of sampler5103939273 Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameShamrock Materials
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifier27E0037 Structure nameSoldier Pile Wall
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number4201A
The truck number from where the sample was collected1434 The batch plant ticket number from where the sample was collected163167
Concrete batch plantShamrock The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedfrom chute Where the material sample would have been placed if not sampledConcrete Waler
From Lot No.Unknown Bag Lot No.Unknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2018-02-15-9-1ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensBang, CT HQ - Sacramento Concrete Testing Laboratory03/15/201803/15/2018
Yes
03/15/2018Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-02-15-9-1 ASTM C39-17a (Verified)