Sample Record

DIME Sample ID 2026-06-16-5

Project Information

Project IdentifiersProject ID: 1001723
DEA: 050N7064
EFIS: 0524000077
DIST-CO-RTE-PM05-SB-101-10.9/12.3
Award DateNot set
Closeout DateNot set
Work DescriptionSB 101 - Segment 4E North - Cabrillo
Location DescriptionNot set
QA Service Level1 (Verified on 11/03/2025)

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

Sample Information

Sample Taken Date06/16/2026 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing06/16/2026 Sample typeQuality Control
A brief description of the sample#7, 3'-8" Welded Hoops The quantity of what the sample constitutes24
From where was the sample collectedFabricator First name of sampler or witnessed byAlexis
Last name of sampler or witnessed byMillan Title of samplerCT METS QA INSPECTOR
Telephone number of sampler9097569960 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameRKR Steel Welding
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL191-090-26
Structure unique identifier Structure name
Bid Item133 - BAR REINFORCING STEEL (BRIDGE)

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)9012357
Hoop Manufacturer Lot Number(s)Lots 1-6 Material Standard CodeASTM A706
Material Grade60 Rebar Size#7
Diameter of Hoop3'-8" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Steel AZ
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
No results found.

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments