Sample Record

DIME Sample ID 2018-03-01-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211848
DEA: 112T2174
EFIS: 1116000131
DIST-CO-RTE-PM11-SD-5-R37.4 - R46.5
Award Date12/22/2016
Closeout Date05/01/2026
Work Description(Alternative Delivery) CMGC, San Elijo Highway Bridge Replacement. Replace the San Elijo lagoon highway bridge, construct HOV lanes, construct bike and pedestrian trails and bridge, build multi-use facility at Manchester Ave.
Location DescriptionIN SAN DIEGO COUNTY IN SOLANA BEACH AND ENCINITAS FROM 0.1 MILE NORTH OF LOMAS SANTA FE DRIVE OVERCROSSING TO 0.2 MILE SOUTH OF BIRMINGHAM DRIVE OVERCROSSING
QA Service Level1 (Verified on 01/31/2017)

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

Sample Information

Sample Taken Date03/01/2018 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing03/05/2018 Sample typeRetest
A brief description of the sampleNo. 8 grade 075 epoxy coated thread bar The quantity of what the sample constitutes125 pcs.
From where was the sample collectedManufacturer First name of sampler or witnessed byKen
Last name of sampler or witnessed byVarela Title of samplerAssociate Steel Inspector
Telephone number of sampler951-229-9279 Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameWilliams Form Eng
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormL08-015-18
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingRetest
Threaded Bar SpecificationASTM A615 Threaded Bar Grade75
Threaded Bar Type Rebar Size8
Nut Specification for Threaded BarN/A System ManufacturerWilliams Form Eng
Epoxy Coating ColorPurple Threaded Bar ApplicationSoil Nail
Coating StandardsASTM A934 epoxy Bar Heat Number(s)100790536
Nut Heat Number(s)N/A Bar Lot NumberN/A
Nut Lot NumberN/A Coupler Heat Number(s)N/A
Coupler GradeN/A

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2018-03-01-1-1ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory03/06/2018
Yes
03/13/2018Public - Test Data Visible
2018-03-01-1-2ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory03/06/2018
Yes
03/13/2018Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-03-01-1-1 ASTM A934-13 (Verified)
DIME Test ID: 2018-03-01-1-2 ASTM A934-13 (Verified)