Sample Record

Owner Lab

  • CT D02 - Redding Northern Regional Laboratory

DIME Sample ID 2026-05-29-49

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 1001306
DEA: 023H7704
EFIS: 0218000039
DIST-CO-RTE-PM02-TEH-99-0.0/12.5
Award DateNot set
Closeout DateNot set
Work DescriptionVINA REHAB: PLACE HMA, INSTALL CULVERTS, AND INSTALL GUARDRAIL.
Location DescriptionTEHAMA COUNTY IN AND NEAR LOS MOLINOS FROM BUTTE COUNTY LINE TO LOS MOLINOS CREEK BRIDGE
QA Service Level1 (Verified on 06/12/2025)

Sample Information

Sample Taken Date05/29/2026 Sample Unique Key49
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/29/2026
Sample typeAcceptance A brief description of the sample1 Bag Subgrade
The quantity of what the sample constitutesSubgrade From where was the sample collectedSource
First name of sampler or witnessed byChris Last name of sampler or witnessed byLee
Title of samplerJET Telephone number of sampler
Laboratory sample identificationD80212 Linked DIME Sample ID
The fabricator/manufacturer/facility nameDeSilva Gates Aggregates Transportation Laboratory (TL) Number681710
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collected02-TEH-99, st.150+00, PM. 2.84
Where the material sample would have been placed if not sampled

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-05-29-49-1CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesJosh Murphy , CT D02 - Redding Northern Regional Laboratory06/02/202606/11/2026
Yes
06/11/2026 
2026-05-29-49-2CTM 301-March 2000: Method for Determining the Resistance "R" Value of Treated and Untreated Bases, Subbases, and Basement Soils by the StabilometerJosh Murphy , CT D02 - Redding Northern Regional Laboratory06/10/202606/11/2026
Yes
06/11/2026R-Val=36 

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2026-05-29-49-1 CTM 202-November 2011 (Verified)
DIME Test ID: 2026-05-29-49-2 CTM 301-March 2000 (Verified)