Sample Record
Owner Lab
- CT HQ - QASI Sacramento Field Office
DIME Sample ID 2026-06-10-3
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 1000710 DEA: 100P9244 EFIS: 1023000226 |
|---|---|
| DIST-CO-RTE-PM | 10-MPA-140-42.0/42.7 |
| Award Date | 08/22/2025 |
| Closeout Date | Not set |
| Work Description | Fergusen Slide Rock Avalanche Shed |
| Location Description | Mariposa County, along Route 140 in the Merced River canyon, about 8 miles east of Briceburg and 7.6 miles west of El Portal. |
| QA Service Level | 1 (Verified on 10/15/2024) |
Sample Information
| Sample Taken Date | 06/10/2026 | Sample Unique Key | 3 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/10/2026 |
| Sample type | Quality Assurance | A brief description of the sample | 4 EA 5ft long epoxy coated strand samples from each spool per SS Section 50-1.01C(5) |
| The quantity of what the sample constitutes | 4 samples from each pack | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Edward | Last name of sampler or witnessed by | Leach |
| Title of sampler | QA Inspector | Telephone number of sampler | 7072903887 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Sumiden | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | 52 - GROUND ANCHOR (SUBHORIZONTAL) |
Material Information
| Material Type | SMTL TM4 - Prestressing Strand | Comments | |
|---|---|---|---|
| Reel/Coil/Pack Number(s) | T350417-3-2, T350418-1-1, T350418-8-1 | Number of Coils | |
| Group Number | Strand Diameter | .6 in | |
| Grade | 270 | Strand Specification | ASTM A 882 |
| Heat Number(s) | T0253276 | Mfg. Lot Number(s) | W76102924-1 |
| Manufacturer(s) | Sumiden Wire Products Corporation |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2026-06-10-3-1 ASTM A882-20 (Verified)
DIME Test ID: 2026-06-10-3-2 ASTM A882-20 (Verified)
DIME Test ID: 2026-06-10-3-3 ASTM A882-20 (Verified)
DIME Test ID: 2026-06-10-3-4 ASTM A882-20 (Verified)
DIME Test ID: 2026-06-10-3-5 ASTM A882-20 (Verified)
DIME Test ID: 2026-06-10-3-6 ASTM A882-20 (Verified)
DIME Test ID: 2026-06-10-3-7 ASTM A882-20 (Verified)
DIME Test ID: 2026-06-10-3-8 ASTM A882-20 (Verified)
DIME Test ID: 2026-06-10-3-9 ASTM A882-20 (Verified)
DIME Test ID: 2026-06-10-3-10 ASTM A882-20 (Verified)
DIME Test ID: 2026-06-10-3-11 ASTM A882-20 (Verified)
DIME Test ID: 2026-06-10-3-12 ASTM A882-20 (Verified)
DIME Test ID: 2026-06-10-3-13 ASTM A882-20 (Verified)