Sample Record
DIME Sample ID 2018-02-20-2
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 211848 DEA: 112T2174 EFIS: 1116000131 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-5-R37.4 - R46.5 |
| Award Date | 12/22/2016 |
| Closeout Date | 05/01/2026 |
| Work Description | (Alternative Delivery) CMGC, San Elijo Highway Bridge Replacement. Replace the San Elijo lagoon highway bridge, construct HOV lanes, construct bike and pedestrian trails and bridge, build multi-use facility at Manchester Ave. |
| Location Description | IN SAN DIEGO COUNTY IN SOLANA BEACH AND ENCINITAS FROM 0.1 MILE NORTH OF LOMAS SANTA FE DRIVE OVERCROSSING TO 0.2 MILE SOUTH OF BIRMINGHAM DRIVE OVERCROSSING |
| QA Service Level | 1 (Verified on 01/31/2017) |
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Information
| Sample Taken Date | 02/20/2018 | Sample Unique Key | 2 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 02/22/2018 | Sample type | Quality Assurance |
| A brief description of the sample | Williams Thread Bars | The quantity of what the sample constitutes | 2 |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Art |
| Last name of sampler or witnessed by | Peterson | Title of sampler | Unknown |
| Telephone number of sampler | Unknown | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | Williams Form |
| Transportation Laboratory (TL) Number | C657886 | Inspector Lot Number from the Transportation Laboratory (TL) Form | L11001318 |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Threaded Bar Specification | ASTM A615 | Threaded Bar Grade | 75 |
| Threaded Bar Type | Deformed | Rebar Size | #8 |
| Nut Specification for Threaded Bar | A108 | System Manufacturer | Williams Form |
| Epoxy Coating Color | Purple | Threaded Bar Application | Threaded Bar |
| Coating Standards | ASTM A934 epoxy | Bar Heat Number(s) | 100790536 |
| Nut Heat Number(s) | 8199326 | Bar Lot Number | Unknown |
| Nut Lot Number | 8P3D | Coupler Heat Number(s) | NA |
| Coupler Grade | NA |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2018-02-20-2-1 ASTM A934-13 (Verified)
DIME Test ID: 2018-02-20-2-2 ASTM A615-15 (Verified)
DIME Test ID: 2018-02-20-2-3 ASTM A615-15 (Verified)