Sample Record

Owner Lab

  • CT D04 - Hayward DME / District Laboratory

DIME Sample ID 2026-04-02-125

Project Information

Project IdentifiersProject ID: 1000707
DEA: 041Q5824
EFIS: 0421000263
DIST-CO-RTE-PM04-SM-101-0/21.8
Award DateNot set
Closeout DateNot set
Work DescriptionREHABILITATE PAVEMENT, UPGRADE SIGNS, GUARDRAIL, AND T
Location DescriptionSAN MATEO COUNTY FROM SAN MATEO COUNTY LINE IN EAST PALO ALTO TO 0.2 MILES NORTH OF COLMA CREEK BRIDGE IN SOUTH SAN FRANCISCO.
QA Service Level1 (Verified on 01/13/2025)

Sample Information

Sample Taken Date04/02/2026 Sample Unique Key125
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing05/07/2026
Sample typeProduction Start-Up A brief description of the sample1/2" RHMA-G
The quantity of what the sample constitutes4 Bags Combined Agg From where was the sample collectedManufacturer
First name of sampler or witnessed byFernando Last name of sampler or witnessed byVega
Title of sampler Telephone number of sampler
Laboratory sample identificationD04-SE-26-009 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan - Pleasanton Transportation Laboratory (TL) NumberSJ-040226-1
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-01-0010
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedConveyor Belt
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number1
Sublot number1 Aggregate Mix Number326122

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-04-02-125-1AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)M. Paulson - Kleinfelder-Hayward, CT D04 - Hayward DME / District Laboratory05/08/202606/10/2026
No
Coarse, 2 faced=96.0%, Coarse, 1 faced=97.7%, Fine, 1 faced=97.5%  
2026-04-02-125-2AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)M. Paulson - Kleinfelder-Hayward, CT D04 - Hayward DME / District Laboratory05/08/202606/10/2026
No
Grading C, 100 revolutions= 4.6%, 500 revolutions= 21.2%  
2026-04-02-125-3AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)M. Paulson - Kleinfelder-Hayward, CT D04 - Hayward DME / District Laboratory05/11/202606/10/2026
No
Average uncompacted voids= 42.8%  
2026-04-02-125-4ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)M. Paulson - Kleinfelder-Hayward, CT D04 - Hayward DME / District Laboratory05/08/202606/10/2026
No
Flat and elongated particles=0%  

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2026-04-02-125-1 AASHTO T335-09r13
DIME Test ID: 2026-04-02-125-2 AASHTO T96-02r10
DIME Test ID: 2026-04-02-125-3 AASHTO T304-11
DIME Test ID: 2026-04-02-125-4 ASTM D4791-10