Sample Record

DIME Sample ID 2026-05-29-40

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 1002224
DEA: 010N9504
EFIS: 0124000146
DIST-CO-RTE-PM01-HUM-101,299-unknown
Award Date04/06/2026
Closeout DateNot set
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 05/26/2026)

Owner Labs

  • Kwik Bond Polymers
  • CT HQ - Sacramento Concrete Testing Laboratory

Sample Information

Sample Taken Date05/29/2026 Sample Unique Key40
Date that the sample was received by the laboratory/organization performing the testing06/01/2026 Sample typeQuality Control
A brief description of the sample1 gallon can / PPC 1121 RESIN The quantity of what the sample constitutes16 totes
From where was the sample collectedSource First name of sampler or witnessed byGILBERTO
Last name of sampler or witnessed byGONZALEZ Title of samplerQuality Control Manager
Telephone number of sampler925-913-9199 Laboratory sample identification26-024
Linked DIME Sample ID The fabricator/manufacturer/facility nameKwik Bond Polymers, Benicia
Transportation Laboratory (TL) Number000217KBP Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypePolyester Mfg. Lot Number(s)AZ6E00832T
Batch NumberAZ6E00832T Mix numberAZ6E00832T

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-05-29-40-1ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational ViscometerGilberto Gonzalez, CT HQ - Sacramento Concrete Testing Laboratory06/04/202606/26/2026
Yes
06/26/2026Accepted supplier's result.Public - Test Data Visible
2026-05-29-40-2ASTM D1475-Nov13: Standard Test Method For Density of Liquid Coatings, Inks, and Related ProductsGilberto Gonzalez, CT HQ - Sacramento Concrete Testing Laboratory06/04/202606/26/2026
Yes
06/26/2026Accepted supplier's result.Public - Test Data Visible
2026-05-29-40-3ASTM D2369-Jul10: Standard Test Method for Volatile Content of CoatingsGilberto Gonzalez, CT HQ - Sacramento Concrete Testing Laboratory06/04/202606/26/2026
Yes
06/26/2026Accepted supplier's result.Public - Test Data Visible
2026-05-29-40-4ASTM D638-Dec14: Standard Test Method for Tensile Properties of PlasticsLaura Bird, CT HQ - Sacramento Concrete Testing Laboratory06/04/202606/26/2026
Yes
06/26/2026Accepted supplier's result.Public - Test Data Visible
2026-05-29-40-5CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and StructuresGilberto Gonzalez, CT HQ - Sacramento Concrete Testing Laboratory06/04/202606/26/2026
Yes
06/26/2026Accepted supplier's result. Only two samples were tested.Public - Test Data Visible
2026-05-29-40-6SCAQMD 309-91-Feb93: Determination of Static Volatile EmissionsGilberto Gonzalez, CT HQ - Sacramento Concrete Testing Laboratory06/03/202606/26/2026
Yes
06/26/2026Accepted supplier's result.Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2026-05-29-40-1 ASTM D2196-Feb15 (Verified)
DIME Test ID: 2026-05-29-40-2 ASTM D1475-Nov13 (Verified)
DIME Test ID: 2026-05-29-40-3 ASTM D2369-Jul10 (Verified)
DIME Test ID: 2026-05-29-40-4 ASTM D638-Dec14 (Verified)
DIME Test ID: 2026-05-29-40-5 CTM 551-August 2012 (Verified)
DIME Test ID: 2026-05-29-40-6 SCAQMD 309-91-Feb93 (Verified)