Sample Record

DIME Sample ID 2018-02-01-6

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210794
DEA: 062HT104
EFIS: 0612000287
DIST-CO-RTE-PM06-FRE-99-23.5/26.7
Award Date06/30/2016
Closeout Date09/16/2020
Work Description(Alternative Delivery) Realign Freeway CONTACT SMR PRIOR TO PERFORMING ANY TESTING OR INSPECTION. CMGC PROJECT. Realign Route 99 between Ashlan Avenue and Olive Avenue to accommodate the High Speed Train (HST).
Location DescriptionState Highway 99 in Fresno (Fresno County) from 0.2 miles North of Olive Ave over-crossing to 0.2 miles North of Ashlan Ave over-crossing.
QA Service Level1 (Verified on 10/01/2015)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date02/01/2018 Sample Unique Key6
Date that the sample was received by the laboratory/organization performing the testing02/09/2018 Sample typeQuality Assurance
A brief description of the sampleDextra Coupler The quantity of what the sample constitutes4
From where was the sample collectedManufacturer First name of sampler or witnessed byDan
Last name of sampler or witnessed byChapa Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameMartinez steel CMC
Transportation Laboratory (TL) NumberC876720 Inspector Lot Number from the Transportation Laboratory (TL) FormNA
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC Rebar
Coupler ManufacturerDextra America Intermediate Assembler or FabricatorUnknown
Rebar Size#10 Coupler ModelBartec
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)4493 Rebar Heat Number(s)4072164, 4072162
Rebar Size 2 Not set Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2018-02-01-6-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory02/09/201802/09/2018
Yes
02/16/2018OK NeckingPublic - Test Data Visible
2018-02-01-6-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory02/09/201802/09/2018
Yes
02/16/2018OK NeckingPublic - Test Data Visible
2018-02-01-6-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory02/09/201802/09/2018
Yes
02/16/2018OK NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-02-01-6-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-02-01-6-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-02-01-6-3 CTM 670-December 2013 (Verified)