Sample Record
Owner Lab
- CT HQ - QASI Bay Area Field Office
DIME Sample ID 2026-05-20-22
Project Information
| Project Identifiers | Project ID: 1001438 DEA: 051M4004 EFIS: 0519000136 |
|---|---|
| DIST-CO-RTE-PM | 05-SCR-9-6.3/7.2 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | CONSTRUCT SIDEWALKS, CURB RAMPS, DRIVEWAYS AND RETAINING WALLS. |
| Location Description | SANTA CRUZ COUNTY FROM 0.1 MILE NORTH OF KIRBY STREET TO 0.1 MILE NORTH OF FALL CREEK DRIVE |
| QA Service Level | 1 (Verified on 07/28/2025) |
Sample Information
| Sample Taken Date | 05/20/2026 | Sample Unique Key | 22 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/01/2026 |
| Sample type | Quality Assurance | A brief description of the sample | A325 Hex Bolt |
| The quantity of what the sample constitutes | 6 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Lund |
| Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 8014626352 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Universal Industrial Sales Inc | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | na |
|---|---|---|---|
| Heat Number(s) | 10716330 | Nut Mfg. Lot Number(s) | na |
| Washer Mfg. Lot Number(s) | na | Bolt Specification | A325 |
| Bolt Length(s) | 2.0" | Nut Specification | na |
| Washer Specification | na | Finish | HD |
| Diameter/Size | 1/2" | Bolt Mfg. Lot Number | L572X1 |
| Rocap Test Requirement(s) | na | Lubricant Requirements(s) | na |
| Washer Inner Diameter(s) | na |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| 2026-05-20-22-1 | ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter) | Andrew Auvinen, CT HQ - Sacramento Structural Materials Testing Laboratory | 06/02/2026 | 06/02/2026 | No |
Test File Attachments
DIME Test ID: 2026-05-20-22-1 ASME B1.2-83r17